background image

© Danfoss

 

FT1380 Crimp Machine Operator’s Manual

14 | © Danfoss FT1380 Crimp Machine Operator’s Manual | 2022.12. 

 

AQ435955684211en-000101

Electrical Schematics

Terminal Blocks and Pin Numbers   
(115V and 230V models)

Terminal Block  

 

Pin Number  

 

Voltage    

 

Wire Color 

 

Description 

TB1 

  1 

 

  +12V 

AC 

 

  Black 

 

  From 

transformer 

 

(2 

wires) 

        Black 

 

  To 

work 

light 

TB2 

  2 

  +0V 

AC 

  White 

 

  From 

transformer 

(2 

wires) 

        White 

 

  To 

work 

light 

TB1 

 

  3 

 

  None 

 

  Green 

 

  To 

earth 

ground 

TB2 

  1 

  +4.04V 

DC 

  Orange 

 

  To 

transducer 

TB2  

 

 

       

 

+4.04 to 0.04V DC*    

Red  

 

 

To transducer 

TB2 

 

  3 

 

  +0.04V 

DC 

  Brown 

 

  To 

transducer 

TB2 

 

  4 

 

  +5V 

DC 

 

  Red 

 

  Crimp 

switch 

TB2 

 

  5 

 

  0V 

DC 

 

  White 

  Switch 

common 

TB2 

 

  6 

 

  +5V 

DC 

 

  Red 

 

  Retract 

switch 

TB3 

 

  1 

 

  +24V 

AC 

 

  Orange 

 

  To 

dump 

valve 

TB3 

 

  2 

 

  +24V 

AC 

 

  Red 

 

  To 

motor 

contractor

* The voltage at TB2 pin 2 varies between 4.04V DC and 0.04V DC, depending on the position of the crimp ring.

Summary of Contents for FT1380

Page 1: ...Operator s Manual Danfoss FT1380 Crimp Machine CAUTION It is recommended this booklet be read prior to set up then used as a guide during actual assembly Retain for reference purposes...

Page 2: ...Instructions 5 Loading and Unloading Die Cages 5 Operating the Keypad 5 6 Entering a Number into the Display 6 Storing a Number from the Display 6 Recalling a Number from the Display 6 Crimping Proced...

Page 3: ...ke hose assemblies using only Danfoss hose and fittings specified for this assembly equipment 6 Verify correct crimp diameters Check and verify correct crimp diameters of all fittings after crimping D...

Page 4: ...unit 3 CAUTION Failure to do so will cause cavitation and damage to the pumping mechanism Hand tighten the vent cap CAUTION Provide electrical service with a dedicated circuit per the crimp machine e...

Page 5: ...ched the setting entered on the keypad this is when crimp is complete Operating the Keypad 1 The DISPLAY shows the three digit setting that will determine the crimp diameter The ratio of the crimp dia...

Page 6: ...ENTER button will illuminate 3 Press three numerical buttons in less than five seconds If more than five seconds elapse the display reverts back to its previous setting After the third number is enter...

Page 7: ...at any point by momentarily depressing the RETRACT switch and then resumed by depressing and holding the RETRACT switch 5 Verify correct crimp diameter Reminder Full retraction is required for changi...

Page 8: ...g since the numbers are a direct ratio Part II 1 Enter in the value of 400 using the keypad Don t hit enter 2 Center a TTC Z Series 12 fitting without a hose in the die cage holding the socket or fitt...

Page 9: ...ge maintenance should be performed at 1000 crimp intervals or every six months whichever occurs first Die cages should be free of grease and debris and inspected for worn or damaged components a The s...

Page 10: ...ate the source of leak If the hose assembly is leaking tighten or replace it If the pump or cylinder is leaking refer to the ENERPAC Repair Parts Sheets Slight oil seepage of the cylinder is normal Pu...

Page 11: ...rew 8 32 x 3 8 SHCS 8 13 ET4020C 0002 Main Guard 1 14 FT1380 3 5 Transducer Assembly 1 15 FT1380 3 17 Bracket Transducer Rod 1 16 FT1380 3 16 Bracket Transducer 1 17 FT1380 3 21 Nut 2 Detail Part Numb...

Page 12: ...d 1 FT1330 2 9 21 FT1330 2 9 2 FT1330 2 9 21 Die Spring 8 or 16 2 FT1380 2 9 3 FT1380 2 9 2 FT1381 2 9 3 Front Plate 1 3 FT1330 2 9 13 FT1330 2 9 3 FT1330 2 9 13 Spring Plate 1 4 FT1330 2 9 55 FT1330...

Page 13: ...achine Operator s Manual AQ435955684211en 000101 Danfoss FT1380 Crimp Machine Operator s Manual 2022 12 13 Electrical Schematics Electrical Schematic for FT1380 115 115V model Electrical Schematic for...

Page 14: ...ires Black To work light TB2 2 0V AC White From transformer 2 wires White To work light TB1 3 None Green To earth ground TB2 1 4 04V DC Orange To transducer TB2 2 4 04 to 0 04V DC Red To transducer TB...

Page 15: ...s Manual AQ435955684211en 000101 Danfoss FT1380 Crimp Machine Operator s Manual 2022 12 15 Hydraulic Schematic SEQUENCE 1 Pump on Cylinder advances 2 Valve energized Cylinder retracts 3 Pump and valv...

Page 16: ...ss hoses fittings and tooling provide the ultimate fluid conveyance solutions for a variety of equipment and applications around the world We proudly engineer to support a sustainable future for tomor...

Reviews: