background image

Technical Information

H1 Axial Piston Single Pumps

Size 069/078

powersolutions.danfoss.com

Summary of Contents for H1P 078

Page 1: ...Technical Information H1 Axial Piston Single Pumps Size 069 078 powersolutions danfoss com ...

Page 2: ...C CCO and Swash Angle Sensor options added GA March 2014 Converted to Danfoss layout DITA CMS FA April 2013 FDC option added EA Feb 2013 AC section added DA Dec 2012 Size 69 added CA Jun 2010 New EC directive BA Jul 2009 First edition AA Technical Information H1 Axial Piston Single Pumps Size 069 078 2 Danfoss May 2017 11062169 BC00000058en US0801 ...

Page 3: ...12 V and B1 24 V 24 Control Response 25 FNR response time 060 068 25 Non Feedback Proportional Electric Control NFPE 26 NFPE control signal requirements H1P 069 078 27 Control Response 29 NFPE response time H1P 069 078 29 Automotive Control AC 30 Mode types 30 Basic functions 30 Performance functions 31 Protection and safety functions 31 Engine control and protection 31 Installation features 31 Fa...

Page 4: ...trol MDC option M1 56 H1P 069 078 Manual Displacement Control MDC with CCO option M3 M4 57 H1P 069 078 Manual Displacement Control MDC with NSS option M2 58 H1P 069 078 Manual Displacement Control MDC with NSS and CCO option M5 M6 59 Forward Neutral Reverse FNR with manual override option A9 12 V B1 24 V 60 Non Feedback Proportional Electric control NFPE with MOR option A8 12 V B8 24 V 61 Non Feed...

Page 5: ... 77 in3 Flow at rated continuous speed 243 l min 53 5 US gal min 273 l min 72 US gal min Torque at maximum displacement theoretical 1 1 N m bar 672 lbf in 1000 psi 1 24 N m bar 758 lbf in 1000 psi Mass moment of inertia of rotating components 0 0077 kg m2 0 0057 slug ft2 0 0094 kg m2 0 00693 slug ft2 Mass weight dry 56 kg 123 lb without charge pump or auxiliary mounting flange Oil volume 2 l 0 5 U...

Page 6: ...bar absolute 24 in Hg vacuum Maximum 4 bar 58 psi Case pressure Rated 3 bar 44 psi Maximum 5 bar 73 psi Lip seal external maximum pressure 0 4 5 8 psi 1 Performance pressure and displacement may be limited due to limited control pressure 2 Full performance pressure and displacement possible at minimum charge and control pressure supply Fluid Specifications Viscosity and Temperature range Feature U...

Page 7: ...tions of the unit External radial shaft loads impact lifetime For lifetime calculations please contact your Danfoss representative The maximum allowable radial load Re is based on the maximum external moment Me and the distance L from the mounting flange to the load It may be determined using the following formula Re Me L Radial load position P003 318E L 270 Re Re Me 180 Re 90 Re 0 Re Me shaft mom...

Page 8: ...ve continuously applied external loads exceeding 25 of the maximum allowable radial load Re or the pump swashplate is positioned on one side of center all or most of the time Mounting flange loads H1P 069 078 The moments shown below apply for top or side control orientation Mounting flange loads Size 069 078 P001 916 MR MS Rated moment MR 3700 N m 32 750 lbf in Shock load moment MS 7900 N m 69 920...

Page 9: ...haft speeds Contact your Danfoss representative for application assistance if your application includes any of these conditions Charge pump flow and power curves 14 17 cm Charge pressure 20 bar 290 psi Viscosity 11 mm s 63 SUS Temperature 80 C 176 F Charge pump power requirements 0 0 1 0 9 0 8 0 7 0 6 0 5 0 4 0 2 0 3 0 1 2 3 4 5 6 HP kW 17 cm 3 1 04 in 3 rev 14 cm 3 0 85 in 3 rev P003 336E 0 500 1...

Page 10: ...nnector A2 EDC 12 V A3 EDC 24 V A4 EDC 12 V A5 EDC 24 V E7 EDC 12 V E8 EDC 24 V To be used for the control Not to be used for the control D Controls continued Non Feedback Proportional Electric Control NFPE Code Control type Voltage MOR CCO with key C Angle sensor DEUTSCH Connector N1 NFPE 12 V N2 NFPE 24 V N3 NFPE 12 V N4 NFPE 24 V N5 NFPE 12 V N6 NFPE 24 V N7 NFPE 12 V N8 NFPE 24 V Align with op...

Page 11: ...nt Control MDC Code Control type CCO Voltage CCO Neutral Start Switch DEUTSCH Connector M1 MDC M2 MDC M3 MDC 12 V M4 MDC 24 V M5 MDC 12 V M6 MDC 24 V Align with options F Orifices and Y Settings for adjustment if applicable D Controls continued Fan Drive Control FDC Code Control type Voltage DEUTSCH Connector F1 FDC 12 V F2 FDC 24 V Align with options F Orifices E Displacement limiters M N Overpre...

Page 12: ...m D4 1 0 mm 1 3 mm 1 3 mm D5 0 6 mm 0 6 mm 0 8 mm D6 1 3 mm 1 3 mm D7 3 0 mm E Displacement limiter N None C No limiters with nested springs required for NFPE AC FDC B Adjustable externally D Adjustable externally with nested springs required for NFPE AC FDC Align with option Y Settings for adjustment if applicable ima1444887758105 Technical Information H1 Axial Piston Single Pumps Size 069 078 Ma...

Page 13: ...eth splined shaft 12 24 pitch G9 ISO 3019 1 outer Ø38 mm 4 SAE C C 23 teeth splined shaft 16 32 pitch F1 ISO 3019 1 outer Ø35 mm 4 SAE C 21 teeth splined shaft 16 32 pitch F4 Conical keyed shaft end similar to ISO 3019 1 code 38 3 taper 1 8 key not supplied with pump K Auxiliary mounting pad per ISO 3019 1 Align with option G Endcap selection NN None H1 Flange 82 2 outer Ø19 mm 4 SAE A 11 teeth 16...

Page 14: ... 450 bar 6526 psi L45 450 bar 6526 psi 480 bar 6962 psi Overpressure protection type and setting for FDC F01 150 bar 2175 psi 250 bar 3630 psi F02 150 bar 2175 psi 300 bar 4350 psi F03 150 bar 2175 psi Available for 069 only 350 bar 5080 psi High pressure relief valve with bypass pressure protection type must be the same for side A and B K1 Pressure setting2 K18 180 bar 2610 psi K20 200 bar 2900 p...

Page 15: ...on Align with options N and S V Charge pressure relief setting 20 20 bar 290 psi Not to be used for NFPE AC and FDC controls 22 22 bar 319 psi 24 24 bar 348 psi 26 26 bar 377 psi 28 28 bar 406 psi 30 30 bar 435 psi 32 32 bar 464 psi 34 34 bar 493 psi W Special hardware features PN EDC FNR MDC valve plate P1 NFPE valve plate Align with options D and E P2 NFPE FDC AC valve plate and speed ring on th...

Page 16: ...D3E in out E N1 12 VDC AC 1 D3F in out F D4E in out E N2 24 VDC D4F in out F D5F in out F P8 12 VDC AC 2 with Swash Plate Angle Sensor D5J in out J D6F in out F P9 24 VDC D6J in out J M00 MDC handle standard position NNN None available option not available option Technical Information H1 Axial Piston Single Pumps Size 069 078 Master Model Code 16 Danfoss May 2017 11062169 BC00000058en US0801 ...

Page 17: ...trol spool could stick and cause the pump to stay at some displacement A serviceable 125 μm screen is located in the supply line immediately before the control porting spool Electrical Displacement Control with hydraulic schematic P003 191 Feedback from Swash plate P T F00B M14 C1 C2 F00A P003 478E Pump displacement vs control current P003 479E 0 b a b a 100 100 Displacement Current mA EDC Control...

Page 18: ...7 52 Ω Inductance 33 mH 140 mH PWM signal frequency Range 70 200 Hz Recommended 200 Hz IP Rating IEC 60 529 IP 67 DIN 40 050 part 9 IP 69K with mating connector Connector color Black PWM signal required for optimum control performance Pump output flow direction vs control signal Shaft rotation CW CCW Coil energized C1 C2 C1 C2 Port A out in in out Port B in out out in Servo port pressurized M4 M5 ...

Page 19: ...oper orifice selection for the desired response H1 pumps are limited in mechanical orificing combinations Mechanical servo orifices are to be used only for fail safe return to neutral in the event of an electrical failure Typical response times at the following conditions p 250 bar 3626 psi Viscosity and temperature 30 mm s 141 SUS and 50 C 122 F Charge pressure 20 bar 290 psi Speed 1800 min 1 rpm...

Page 20: ...tion the control spool could stick and cause the pump to stay at some displacement A serviceable 125 μm screen is located in the supply line immediately before the control porting spool The MDC is sealed by means of a static O ring between the actuation system and the control block Its shaft is sealed by means of a special O ring which is applied for low friction The special O ring is protected fr...

Page 21: ...tic of the linkages must ensure that either control shaft is protected from torque overload To avoid an overload of the MDC customers must install any support to limit the setting range of the Bowden cable C Caution Using the internal spring force on the input shaft is not an appropriate way to return the customer connection linkage to neutral MDC Shaft Rotation CCW CW P301 753 MDC shaft rotation ...

Page 22: ...0 6 4 2 s 3 1 s C9 1 0 6 3 9 s 2 9 s D1 1 0 8 2 5 s 1 9 s D2 1 3 0 8 2 2 s 1 7 s D3 1 3 1 1 6 s 1 2 s D4 1 3 1 3 1 3 1 1 9 s 1 5 s D5 0 6 0 8 0 8 0 6 7 5 s 4 4 s D6 1 3 1 3 1 9 s 1 5 s Neutral Start Switch NSS The Neutral Start Switch NSS contains an electrical switch that provides a signal of whether the control is in neutral The signal in neutral is Normally Closed NC Neutral Start Switch schema...

Page 23: ...g connector kit 1 K29657 Case Gauge Port M14 The drain port should be used when the control is mounted on the unit s bottom side to flush residual contamination out of the control MDC schematic diagram P005 701 M14 M5 M4 M3 Lever MDC controls are available with an integrated lever Technical Information H1 Axial Piston Single Pumps Size 069 078 Control Options Danfoss May 2017 11062169 BC00000058en...

Page 24: ...e electric control FNR P003 193 FNR hydraulic schematic P003 189 C2 C1 F00A M14 T P F00B Pump displacement vs electrical signal P003 190E 100 0 100 Voltage VDC Displacement Control current Voltage Min current to stroke pump Pin connections 12 V 750 mA any order 24 V 380 mA 1 2 P003 480 Connector ordering data Description Quantity Ordering data Mating connector 1 DEUTSCH DT06 2S Wedge lock 1 DEUTSC...

Page 25: ...cal failure The time required for the pump output flow to change from zero to full flow acceleration or full flow to zero deceleration is a net function of spool porting orifices and charge pressure A swashplate response table is available for each frame indicating available swashplate response times Testing should be conducted to verify the proper orifice selection for the desired response H1 pum...

Page 26: ...tional Electric Control P003 192 NFPE schematic P003 188 C2 C1 F00A M14 T P F00B The pump displacement is proportional to the solenoid signal current but it also depends upon pump input speed and system pressure This characteristic also provides a power limiting function by reducing the pump swashplate angle as system pressure increases A typical response characteristic is shown in the accompanyin...

Page 27: ... higher or lower value 1 2 P003 480 Connector ordering data Description Quantity Ordering data Mating connector 1 DEUTSCH DT06 2S Wedge lock 1 DEUTSCH W2S Socket contact 16 and 18 AWG 2 DEUTSCH 0462 201 16141 Danfoss mating connector kit 1 K29657 Solenoid data Description 12 V 24 V Maximum current 1800 mA 920 mA Nominal coil resistance 20 C 68 F 3 66 Ω 14 20 Ω 80 C 176 F 4 52 Ω 17 52 Ω Inductance ...

Page 28: ...timum control performance Pump output flow direction vs control signal Shaft rotation CW CCW Coil energized C1 C2 C1 C2 Port A in out out in Port B out in in out Servo port pressurized M5 M4 M5 M4 For coil location see Installation drawings Technical Information H1 Axial Piston Single Pumps Size 069 078 Control Options 28 Danfoss May 2017 11062169 BC00000058en US0801 ...

Page 29: ... to verify the proper orifice selection for the desired response H1 pumps are limited in mechanical orificing combinations Mechanical servo orifices are to be used only for fail safe return to neutral in the event of an electrical failure Typical response times at the following conditions p 250 bar 3626 psi Viscosity and temperature 30 mm s 141 SUS and 50 C 122 F Charge pressure 20 bar 290 psi Spe...

Page 30: ...defined as mode types which can be used individually Automotive Load dependent torque controlled driving behavior Setpoint for the drive curve is the engine rpm Non Automotive Load independent speed controlled driving mode Setpoint for the drive curve is a Joystick or drive pedal signal independent of the engine rpm The best performance will achieved with an AC 2 Swash Plate Angle Sensor Creep Aut...

Page 31: ...e speed check battery check and FNR must be in neutral etc Operator presence detection Hydraulic system overheat and low temperature protection Hydraulic motor over speed protection Park brake test mode for roller applications to fulfill SAE J1472 EN500 4 SIL2 compliant Engine control and protection CAN J1939 engine interface Engine speed control via drive pedal with safety controlled monitoring f...

Page 32: ...est response and maximize system stability Additionally pressure limiter PL valves are used to limit maximum fan trim speed in both forward and reverse directions FDC control P301 441 FDC hydraulic schematic P T F00B M14 C1 C2 F00A P301 442 H1 pumps with FDC will be delivered from factory with nominal PL setting of 150 bar 2175 psi The PL must be re adjusted to ensure that the fan reaches the desi...

Page 33: ...e pressure A swashplate response table is available for each frame indicating available swashplate response times Testing should be conducted to verify the proper orifice selection for the desired response H1 pumps are limited in mechanical orificing combinations Mechanical servo orifices are to be used only for fail safe return to neutral in the event of an electrical failure Typical response tim...

Page 34: ...g the MOR function The MOR plunger has a 4 mm diameter and must be manually depressed to be engaged Depressing the plunger mechanically moves the control spool which allows the pump to go on stroke The MOR should be engaged anticipating a full stroke response from the pump W Warning An o ring seal is used to seal the MOR plunger where initial actuation of the function will require a force of 45 N ...

Page 35: ...mA Short circuit output current to supply or GND1 7 5 mA Sensitivity 70 0 mV deg 78 0 mV deg 85 8 mV deg Working range swashplate angle 18 C 0 C 18 C Correlation between signals 1 and 22 475 mV 500 mV 525 mV 1 Up to duration of 2 5 seconds at 25 C 2 Signal 1 nominal is lower than signal 2 redundant Swash plate angle sensor connector Pin assignment 1 2 3 4 1 Ground GND 2 Output Signal 2 SIG2 Second...

Page 36: ...size max displacement Actual displacement Speed rpm Delta pressure Viscosity and temperature The displacement can be calculated by cc V tan α V tan 18 The corresponding flow is l min Q V n hvol 1000 Interface with ECU Interface with ECU schematic ECU V Sig1 Sig2 Gnd E3 340R 340R Out 2 Out 1 VCC VCC Gnd Gnd 340R 340R 0 1uF 5 6 nF 5 6 nF E2 E1 Minimum recommended load resistance is 100 kΩ Technical ...

Page 37: ...wed to reach the pump control The X7 logic port will also be connected to charge pressure and flow The solenoid control is intended to be independent of the primary pump control making the control cut off an override control feature It is however recommended that the control logic of the CCO valve be maintained such that the primary pump control signal is also disabled whenever the CCO valve is de...

Page 38: ...otection class IP67 IP69K with mating connector Bi directional diode cut off voltage 28 V 53 V Brake gauge port with MDC C Caution It is not recommended to use brake port for any external flow consumption to avoid malfunction of CCO function Technical Information H1 Axial Piston Single Pumps Size 069 078 Control Options 38 Danfoss May 2017 11062169 BC00000058en US0801 ...

Page 39: ...ge The adjustment screw can be completely removed from the threaded bore if backed out to far P003 266 Displacement change approximately H1P 069 078 Parameter Size 069 078 1 Turn of displacement limiter screw 7 4 cm3 0 45 in3 Internal wrench size 4 mm External wrench size 13 mm Torque for external hex seal lock nut 24 N m 212 lbf in For more information see H1 Axial Piston Pumps Service Manual AX0...

Page 40: ...ng must not protrude beyond this surface 48 1 1 890 0 039 31 5 1 1 240 0 039 P003 265E Specifications Option G1 Spline 14 teeth 12 24 pitch Min active spline length1 31 45 mm 1 238 in Torque rating2 Rated 534 N m 4720 lbf in Maximum 816 N m 7220 lbf in 1 Minimum active spline length for the specified torque ratings 2 For definitions of maximum and rated torque values refer to Basic Information 110...

Page 41: ...lat root side fit Per Ansi B92 1 1996 Class 5 54 1 2 126 0 039 40 5 1 1 594 0 039 P003 264E Specifications Option G9 Spline 23 teeth 16 32 pitch Min active spline length1 40 33 mm 1 588 in Torque rating2 Rated 999 N m 8840 lbf in Maximum 1818 N m 16 090 lbf in 1 Minimum active spline length for the specified torque ratings 2 For definitions of maximum and rated torque values refer to Basic Informa...

Page 42: ...fit Per Ansi B92 1 1996 Class 5 Coupling must not protrude beyond this surface P003 263E Specifications Option F1 Spline 21 teeth 16 32 pitch Min active spline length1 34 5 mm 1 358 in Torque rating2 Rated 760 N m 6730 lbf in Maximum 1137 N m 10 060 lbf in 1 Minimum active spline length for the specified torque ratings 2 For definitions of maximum and rated torque values refer to Basic Information...

Page 43: ...stener grade 5 Tapered shaft customer acknowledgement The Danfoss H1 tapered shaft has been designed using the industry standard ISO 3019 1 minus the through hole in the end of the shaft Danfoss recommends a self locking nut instead of a castle nut and pin The nut and mating square cut key are customer supplied The specified torque rating of the tapered shaft is based on the cross sectional diamet...

Page 44: ... Class 6 8 101 0 25 0 319 0 010 O ring seal required Ref 82 22 3 237 i D 2 62 0 103 cross section 1 956 0 077 Mounting flange surface Flange 82 2 per ISO 3019 1 To be paint free 61 68 2 428 Auxiliary pump Shaft length Specifications Option H2 Spline 9 teeth 16 32 pitch Maximum torque1 162 N m 1430 lbf in 1 For definitions of maximum and rated torque values refer to Basic Information 11062168 secti...

Page 45: ... required Ref 82 22 3 237 i D 2 62 0 103 cross section R0 8 MAX 0 031 0 780 039 0 19 801 1 0 1 956 0 077 8 1 0 25 0 319 0 010 61 68 MAX Auxiliary pump Shaft length Mounting flange surface Flange 82 2 per ISO 3019 1 To be paint free Specifications Option H1 Spline 11 teeth 16 32 pitch Maximum torque1 296 N m 2620 lbf in 1 For definitions of maximum and rated torque values refer to Basic Information...

Page 46: ...ss 6 R0 8 MAX 0 031 O ring seal required Ref 101 32 3 989 id X 2 62 0 103 cross section Mounting flange surface Flange 101 2 per ISO 3019 1 To be paint free 61 68 2 428 Auxiliary pump shaft length 295 459 2 11 63 0 079 Specifications Option H3 Spline 13 teeth 16 32 pitch Maximum torque1 395 N m 3500 lbf in 1 For definitions of maximum and rated torque values refer to Basic Information 11062168 sec...

Page 47: ...989 id x 2 62 103 cross section 295 486 2 11 633 0 079 1 956 0 077 11 4 0 25 0 449 0 010 0 780 0 039 0 19 8 1 0 Mounting flange surface Flange 101 2 per ISO 3019 1 To be paint free 61 68 2 428 Auxiliary pump Shaft length Specifications Option H5 Spline 15 teeth 16 32 pitch Maximum torque1 693 N m 6130 lbf in 1 For definitions of maximum and rated torque values refer to Basic Information 11062168 s...

Page 48: ...r of teeth 14 Pitch fraction 12 24 Pressure angle 30 Pitch 29 633 1 167 Typ of fit fillett root side fit Per ansi b92 1 1996 class 6 min active spline length 14 3mm 297 907 2 11 729 0 079 Mounting flange surface Flange 127 4 per ISO 3019 1 To be paint free 63 86 2 514 Auxiliary pump Shaft length Specifications Option H6 Spline 14 teeth 12 24 pitch Maximum torque1 816 N m 7220 lbf in 1 For definiti...

Page 49: ... 0 039 2x wrench size 4 2x wrench size 13 150 MAX 5 906 150 MAX 5 906 P003 255E Please contact Danfoss representative for specific installation drawings Technical Information H1 Axial Piston Single Pumps Size 069 078 Dimensions Danfoss May 2017 11062169 BC00000058en US0801 49 ...

Page 50: ...depth Recommended screw in depth 1 5 x thread dia System port A 25 4 450bar Split flange boss Per ISO 6162 M12 x 1 75 20 min Full thread depth Recommended screw in depth 1 5 x thread dia Charge inlet port S Port ISO 11926 1 1 5 16 12 63 max clearance dia for fitting System A gauge port MA Port ISO 11926 1 9 16 18 28 max clearance dia for fitting Connector Deutsch DT04 2P To be paint free Please co...

Page 51: ...in port L2 Port ISO 11926 1 1 1 16 12 48 max clearance dia for fitting Charge pressure construction port Port ISO 11926 1 5 16 24 Charge gauge port M3 Port ISO 11926 1 9 16 18 28 max clearance dia for fitting After filtering Connector Deutsch DT04 2P To be paint free P003 325E Ports description Port Description Size A B System ports A and B Ø 25 4 mm E Charge filtration port from filter 7 8 14 F C...

Page 52: ... 0 8 0 32 0 03 15 0 2 0 59 0 01 Case drain port L4 Port ISO 11926 1 1 1 16 12 48 0 max clearance dia for fitting Case pressure port Port ISO 11926 1 7 8 14 42 0 max clearance dia for fitting Servo gauge port M4 Port ISO 11926 1 7 16 20 21 max clearance dia for fitting Charge inlet port S Port ISO 11926 1 1 5 16 12 63 0 max clearance dia for fitting System port B 25 4 450 bar Split flange boss per ...

Page 53: ...ax clearance dia for fitting Charge filtration port F 20 47 Port ISO 11926 1 7 8 14 42 0 max clearance dia for fitting to filter Charge filtration port E Port ISO 11926 1 7 8 14 42 0 max clearance dia for fitting from filter F F E E Y 231 415 1 9 111 0 039 235 515 1 9 272 0 039 232 515 1 9 154 0 039 77 2 1 3 039 0 039 67 1 2 638 0 039 7 1 0 276 0 039 53 5 1 2 106 0 039 System B gauge port MB Port ...

Page 54: ...010 Other side screw Head space 4x 57 25 0 25 2 254 0 010 4x w 14 34 0 19 0 565 0 007 4x 57 249 0 25 2 254 0 010 CCW Rotation CW Rotation P003 328E Please contact Danfoss representative for specific installation drawings Technical Information H1 Axial Piston Single Pumps Size 069 078 Installation drawings 54 Danfoss May 2017 11062169 BC00000058en US0801 ...

Page 55: ...e for specific installation drawings Electric Displacement Control EDC with MOR option A4 12 V A5 24 V 2x 152 86 1 6 018 0 039 2x139 3 1 5 484 0 039 Connector Deutsch DT04 2P To be paint free Connector Deutsch DT04 2P To be paint free 128 4 2 5 055 0 079 64 2 1 2 528 0 039 Case gauge port M14 Port ISO 11926 1 7 16 20 21 max clearance dia for fitting 77 2 1 3 04 0 039 Shaft Mounting flange Shaft 17...

Page 56: ...6 1 2 2x24 0 5 4x M6x1 6H thd 9 min full thd depth paint free Case gauge port M14 ISO 11926 1 7 16 20 Shaft Shaft 0 7 5 1 3x11 0 02 0 08 Control handle shaft Please contact Danfoss representative for specific installation drawings Technical Information H1 Axial Piston Single Pumps Size 069 078 Controls 56 Danfoss May 2017 11062169 BC00000058en US0801 ...

Page 57: ...l Cut Off connector C4 Deutsch DT04 2P paint free Control Cut Off connector C4 Deutsch DT04 2P paint free Case gauge port M14 ISO 11926 1 7 16 20 Brake gauge port X7 ISO 11926 1 7 16 20 152 86 1 2 70052604 D12 72 15 0 8 Shaft Control Cut Off connector C4 Pin Assignment Pin Assignment 1 Supply OR 1 Ground 2 Ground 2 Supply Please contact Danfoss representative for specific installation drawings Tec...

Page 58: ...ee Neutral Start Switch connector Deutsch DT04 2P paint free Case gauge port M14 ISO 11926 1 7 16 20 Shaft Control handle shaft Shaft 9 9 1 0 Neutral Start Switch connector Pin Assignment Pin Assignment 1 Supply OR 1 Ground 2 Ground 2 Supply Please contact Danfoss representative for specific installation drawings Technical Information H1 Axial Piston Single Pumps Size 069 078 Controls 58 Danfoss M...

Page 59: ...trol handle shaft Shaft 9 9 1 0 152 86 1 2 Control Cut Off connector C4 Deutsch DT04 2P paint free Brake gauge port X7 ISO 11926 1 7 16 20 152 86 1 2 72 15 0 8 100 75 0 8 98 774 1 5 Control Cut Off connector C4 Deutsch DT04 2P paint free Shaft Neutral Start Switch connector Control Cut Off connector C4 Pin Assignment Pin Assignment 1 Supply OR 1 Ground 2 Ground 2 Supply Please contact Danfoss repr...

Page 60: ... DT04 2P To be paint free Connector Deutsch DT04 2P To be paint free Case gauge port M14 Port ISO 11926 1 7 16 20 21 max clearance dia for fitting 128 4 2 5 055 0 079 64 2 1 2 528 0 039 209 MAX 8 228 P003 257E Please contact Danfoss representative for specific installation drawings Technical Information H1 Axial Piston Single Pumps Size 069 078 Controls 60 Danfoss May 2017 11062169 BC00000058en US...

Page 61: ...ase gauge port M14 Port ISO 11926 1 7 16 20 21 max clearance dia for fitting Plug removing can cause Contamination issues Shaft 77 2 1 3 04 0 039 Mounting flange 179 28 1 7 058 0 039 2x 152 86 1 6 018 0 039 Shaft 209 MAX 8 228 P003 363E Please contact Danfoss representative for specific installation drawings Technical Information H1 Axial Piston Single Pumps Size 069 078 Controls Danfoss May 2017 ...

Page 62: ...rride C2 Depressing the plunger mechanically moves the control spool Actuation allows full stroke pump response as per coil and rotation dependent control logic Control solenoid connector C1 Deutsch DT04 2P Paint free Plug removing can cause contermination issues Neutral switch connector Deutsch DT04 2P Paint free Control solenoid connector C2 Deutsch DT04 2P Paint free Control solenoid connector ...

Page 63: ...ing the plunger mechanically moves the control spool Actuation allows full stroke pump response as per coil and rotation dependent control logic CC1 Control connector Deutsch DTM04 12P A Paint free CC2 Control connector Deutsch DTM04 12P B Paint free CCC3 Control connector Deutsch DT06 2S Paint free For using connector the plug may be removed CAN Control connector Deutsch DTM04 3P Paint free For u...

Page 64: ...y Use in other systems could result in unintended movement of the machince or its elements Loss of the input signal to this control will cause the pump to produce maximum flow Contact Danfoss or an autorized distributor with questions regarding the use of this product WARNING Control solenoid connector C1 and C2 Pin Assignment Alternative Pin Assignment 1 Supply OR 1 Ground 2 Ground 2 Supply Pleas...

Page 65: ...epresentative for specific installation drawings Remote full charge pressure filtration option P for end cap option F5 SAE C PTO 67 1 2 638 0 039 8 5 1 0 335 0 039 55 5 1 2 185 0 039 System B gauge port MB Port ISO 11926 1 9 16 18 Ø28 max clearance dia for fitting Charge filtration port E Port ISO 11926 1 7 8 14 Ø42 max clearance dia for fitting From filter Charge filtration port F Port ISO 11926 ...

Page 66: ...ing Before filter P003 246E Integral full flow charge pressure filtration with filter bypass sensor option M for end cap option F4 SAE C PTO 53 58 1 2 110 0 039 220 7 1 8 687 0 039 135 268 1 5 326 0 039 276 405 1 10 882 0 039 285 214 1 11 229 0 039 Connector Deutsch DTM04 2P To be paint free 198 267 1 7 806 0 039 77 751 1 3 061 0 039 40 6 1 1 598 0 039 Charge gauge port M6 Port ISO 11926 1 9 16 18...

Page 67: ... 5 16 24 Charge filtration port E Port ISO 11926 1 7 8 14 42 max clearance dia for fitting From filter E E 96 5 1 3 799 0 039 12º Charge filtration port E Port ISO 11926 1 7 8 14 42 max clearance dia for fitting From filter Charge inlet port S Port ISO 11926 1 1 5 16 12 Closed with plug E E P301 299 Please contact Danfoss representative for specific installation drawings Technical Information H1 A...

Page 68: ...Solutions ApS Nordborgvej 81 DK 6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New District Shanghai China 201206 Phone 86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues brochure...

Reviews: