H1P 069/078 Manual Displacement Control (MDC) with CCO, option M3, M4
Mounting flange
50.7±0.8
129.7±1.2
68.5±0.8
73.7±0.8
101.1±0.8
100.75±0.8
98.774±1.5
2x22±0.5
9.8
+1
220.26±2.5
178.16±1.2
152.86±1.2
2x24±0.5
7.5±1°
3x11
-0.02
-0.08
4x M6x1-6H thd.
9 min. full thd. depth
paint free
Shaft
Control handle shaft
Shaft
0
Control Cut Off connector C4:
Deutsch DT04-2P
paint free
Control Cut Off connector C4:
Deutsch DT04-2P
paint free
Case gauge port M14
ISO 11926-1 -7/16-20
Brake gauge port X7
ISO 11926-1 -7/16-20
152.86±1.2
70052604-D12
72.15±0.8
Shaft
Control Cut Off connector C4:
Pin
Assignment
Pin
Assignment
1
Supply
OR
1
Ground
2
Ground
2
Supply
Please contact Danfoss representative for specific installation drawings.
Technical Information
H1 Axial Piston Single Pumps, Size 069/078
Controls
©
Danfoss | May 2017
11062169 | BC00000058en-US0801 | 57