background image

1

Electronic Programmable Room Thermostats
HC75-1 with integral sensor.
HC75A-1 with remote sensor.

SETTING INSTRUCTIONS

SETTING THE CLOCK

After  the  recessed 

RESET

  button

has been pressed the display appears

as  shown,  with  the  colon  blinking,

and all the factory pre-set conditions

will be present.
To set the clock to the correct time,

press and release the button marked

PROG

. The digits blink.

Press the 

DAY

 button (the digits stop

blinking) until the correct day number

is shown. (1 = Monday).
Press and release the

 +

 or 

-

 buttons to change the time by one minute,

or press and hold down to change the time in ten minute steps.
When the time is correct press 

PROG

 to start the clock and continue

setting sequence.

SETTING THE EVENT TIMES & TEMPERATURES

The first event (time and temperature)

is displayed, together with the day or

days when it is active. Note that the

day number(s) displayed will be that

of  the  current  day.  In  7  Day  mode

only  a  single  day  number  will  be

displayed,  in  5/2  Day  mode  either

12345 or 67 will be displayed.
To  step  through  the  six  available

events press and release the 

NEXT

button.
Whilst  each  event  is  on  display,  it

may be altered as required.

Selecting an event time

Press and hold down the 

+

 or

 - 

buttons

to change the event time in ten minute

steps. Press and release to change

by one minute.

Selecting a heating temperature

Press  and  release  the 

s

  button  to

raise  the  HEATING  control

temperature by 0·5°C (1°F), or press and release the 

t

 button to lower

the HEATING control temperature by 0·5°C. Press and hold down

these buttons to make larger changes to the control temperature.

Selecting a cooling temperature

Press  and  release  the    button  to  raise  the  COOLING  control

temperature by 0·5°C (1°F), or press and release the 

 

button to lower

the COOLING control temperature by 0·5°C. Press and hold down

these buttons to make larger changes to the control temperature.

Dead Band

Whilst adjusting the HEATING and COOLING temperatures it will be

noted that the two temperatures never become closer together than

2°C(5°F).  This  designed-in  dead  band  prevents  the  heating  and

cooling equipment from switching simultaneously.

Event No.

Time

Day

AUTO

HEAT

COOL

OFF

AUTO

ON

Cooling

Control

temp.

7 day mode

Event No.

Days

Time

AUTO

HEAT

COOL

OFF

AUTO

ON

Cooling

Control

temp.

Heating

Control

temp.

5/2 day mode

Selecting an 'OFF' event

If there is a demand to turn 'OFF' rather than turn down the heating or

turn up the cooling, for example during unoccupied periods, an 'OFF'

event can be selected.
Selecting a programmed 'OFF' event for heating: use the 

t

 button to

lower the heating set temperature to its minimum value which is 'OFF',

the characters 'OF' will replace the heating control temperature.
Selecting a programmed 'OFF' event for cooling: use the    button to

raise the cooling set temperature to its maximum value which is 'OFF',

the characters 'OF' will replace the cooling control temperature.
When  all  events  for  the  day(s)  on

display are as required press 

DAY

 to

show the following day's events.
The display will appear similar to one

of  the  diagrams  on  the  right,

depending on whether the HC75 has

been  set  up  for  7  day  or  5/2  day

mode.
Use  the  , 

+

,

  -

s

t

,  ,    

NEXT

buttons to alter the events as required,
OR
If the previous day's programme is to

be repeated, press 

COPY

 to repeat

those    events  with  just  one  button

press.
(Pressing 

COPY

 when in 5/2 mode will repeat the events programmed

for days 1 to 5 at the weekend).
Use the 

DAY

 and 

NEXT

 buttons to check all the events programmed,

using the +,-,

s

t

, ,  buttons to make alterations to each event as

necessary.
When all the events for every day are

as required, press 

PROG

 to return to

RUN mode, with the colon blinking.
The heating/cooling system will now

be  controlled  to  provide  the

temperatures  programmed.
Refer  to  the  USER'S  GUIDE  for  details  of  the  manual  over-rides

available during day to day operation.

AUTO

HEAT

COOL

OFF

AUTO

ON

7 day mode

AUTO

HEAT

COOL

OFF

AUTO

ON

5/2 day mode

AUTO

HEAT

COOL

OFF

AUTO

ON

Heating

Control

temp.

Reviews: