Application Guide | iC2-Micro Frequency Converters
Selection number
Selection name
Selection description
39
Start command
This event is True, if frequency converter is started by any means
(digital input or other).
40
Drive stopped
This event is True, if frequency converter is stopped or coasted by
any means (digital input or other).
42
Auto Reset Trip
An auto reset is performed.
50
Comparator 4
Use result of comparator 4 in logic rule.
51
Comparator 5
Use result of comparator 5 in logic rule.
60
Logic rule 4
Use result of logic rule 4 in logic rule.
61
Logic rule 5
Use result of logic rule 5 in logic rule.
83
Lost Load
Lost load is performed.
P 8.4.2.3 Stop Controller
Select the condition (TRUE or FALSE) to deactivate the Smart Logic Controller.
Default value:
40
Parameter type:
Selection
Parameter
number:
1302
Unit:
–
Data type:
enum
Access type:
Read/Write
The following are the selections for the parameter.
Selection number
Selection name
Selection description
0
FALSE
Enters False in logic rule.
1
TRUE
Enters True in logic rule.
2
Running
See
P 9.4.3.1 Function Relay [5]
for description.
3
In range
See
P 9.4.3.1 Function Relay [7]
for description.
4
On reference
See
P 9.4.3.1 Function Relay [8]
for description.
7
Out of current range
See
P 9.4.3.1 Function Relay [12]
for description.
8
Below I low
See
P 9.4.3.1 Function Relay [13]
for description.
9
Above I high
See
P 9.4.3.1 Function Relay [14]
for description.
16
Thermal warning
See
P 9.4.3.1 Function Relay [21]
for description.
17
Mains out of range
Mains voltage is outside the specified voltage range.
18
Reversing
See
P 9.4.3.1 Function Relay [25]
for description.
19
Warning
A warning is active.
20
Alarm (trip)
A trip alarm is active.
21
Alarm (trip lock)
A trip lock alarm is active.
Danfoss A/S © 2024.03 AB413939445838en-000301 / 130R1254 |