19
Gateway InterBus-S
MG.10.G1.51 – VLT is a registered Danfoss trademark
English
Deutsch
OB 20
OB 20
OB 20
OB 20
OB 20
:JU
FB
210
;Initialization of the IBS-module
NAME :ANLAUF
:BE
OB 21
OB 21
OB 21
OB 21
OB 21
:JU
FB
210
;Initialization of the IBS-module
NAME :ANLAUF
:BE
OB 22
OB 22
OB 22
OB 22
OB 22
:JU
FB
210
;Initialization of the IBS-module
NAME :ANLAUF
:BE
OB1
OB1
OB1
OB1
OB1
:JU
FB 62
NAME :CON/IND
IBDB :
DB 9
InterBus Data block
CIDB :
FY 18
CON/IND caption table
T
:
T 1
Timer
TO
:
F 8.3
Time Out
:L
KB 1
:T
FY 201
:O
F 0.0
:ON
F 0.0
:=
F 0.1
:
:A
F 224.1
Activation for Download
:A
F 200.5
Activation for FB1
:JC
FB 1
Parameterization VLT1
NAME :VLT-PARA
STRC :
F 200.0
Auxiliary flag
STR1 :
F 200.1
Auxiliary flag
STR2 :
F 200.2
Auxiliary flag
RDB
:
DB 23
Request-DB
CDB
:
DB 21
Confirmation-DB
VLT
:
FY
201
VLT Address
AKTI
:
F
21.0
Activation for PCP Communication
PKEW :
FW 210
PCA
to the VLT
PARW :
FW 212
Parameter value to the VLT
Example of pr
ogram for Siemens S5-115U