5.11 Flushing
RO membranes require periodic flushing to limit biological fouling.
There are two types of flushing: feed water (Seawater) flush and fresh water (Permeate)
flush.
Regardless of the flush water used, the water must be pre-filtered to the level described in
chapter 5.8. All parts of the iSave must be flushed, i.e. LP- and HP flow channels.
Feed water flushing is part of a normal shutdown sequence. After the HP pump has been
stopped, the permeate and concentrate production will continue until the high-pressure
drops below the osmotic pressure. Both the iSave and the LP seawater feed pump must run
until the conductivity measured at point (7) and (3) are satisfactory. See also P&ID in chapter
5.16.
Fresh water flushing is performed before every extended shutdown of the RO plant.
Permeate is simultaneously fed into the iSave at LP in (2), and either to the HP pump inlet
(1) or through some other injection point such as the CIP connections or full flow cleaning
connection. See also P&ID in chapter 5.16. Permeate may be produced during this flushing
process.
Special attention should be given to the pressure in the HP line (7) as the iSave may start to
cavitate when it runs at high speed and the pressure in the HP line (7) drops below 3 bars.
This can be avoided by reducing the speed of the iSave to about 750 rpm and keeping the
pressure in the HP line at the minimum of 1 bar. At this low pressure the iSave may only run
for a maximum of 10 minutes.
Failing to flush the iSave with fresh water before extended shutdowns may result in ex-
tensive biological growth and cause corrosion in the iSave and other equipment in the RO
system.
5.12 CIP or membrane cleaning
The purpose of membrane cleaning is to reduce scaling and fouling in the membranes. For
optimal performance specific chemicals are required, depending on the cause of the pollu-
tion. After chemical treatment the system must be flushed with fresh water.
The flush water coming out of the membranes may consist of a large amount of suspend-
ed inorganic particles. It is important to assure that these particles are not lead into the
iSave.
It is essential that the water used for the final pre-flush is pre-filtered to a level described
in chapter 5.8.
The iSave should not be exposed to chemicals that will damage the RO membranes
Also see instruction “Membrane cleaning of RO system with iSave unit” in appendix 10.2.
5.13 High pressure remains after shutdown
The HP line of the RO system equipped with an iSave can remain pressurised for a long time
after shutdown. Pressure decreases as water slowly leaks through the iSave. If more rapid
system depressurisation is required, the system should be bled through a suitable valve on
the HP concentrate line.
Always check the pressure in the high-pressure lines before making service in the HP lines
or pressurised equipment.
NB!
Summary of Contents for iSave 21
Page 5: ...User manual iSave 21 5 180R9221 521B1174 DKCFN PS 003 A1 02 1 CE Declaration of conformity...
Page 32: ...User manual iSave 21 32 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 38: ...User manual iSave 21 38 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 43: ...User manual iSave 21 43 180R9221 521B1174 DKCFN PS 003 A1 02 10 3 Data sheet...
Page 44: ...User manual iSave 21 44 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 58: ...User manual iSave 21 58 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 59: ...User manual iSave 21 59 180R9221 521B1174 DKCFN PS 003 A1 02 10 4 iSave part list...
Page 60: ...User manual iSave 21 60 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 61: ...isave danfoss com iSave 21 Parts list 180R9209 DKCFN PC 003 A2 02 Parts list...
Page 66: ...Parts list iSave 21 Parts list 6 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view Vane pump...
Page 68: ...Parts list iSave 21 Parts list 8 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view iSave...
Page 70: ...User manual iSave 21 70 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 71: ...User manual iSave 21 71 180R9221 521B1174 DKCFN PS 003 A1 02 10 5 iSave overload protection...
Page 72: ...User manual iSave 21 72 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 80: ...User manual iSave 21 80 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 82: ...User manual iSave 21 82 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 86: ...User manual iSave 21 86 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 104: ...User manual iSave 21 104 180R9221 521B1174 DKCFN PS 003 A1 02...