User manual
iSave 21
25
180R9221 / 521B1174 / DKCFN.PS.003.A1.02
6.8 Accessibility
With respect to the service and replacement of the complete iSave unit, it is recommended
to maintain sufficient space around the unit.
The space must be sufficient enough to allow for safe lifting of the equipment, with no risk
for personal injury and/or damage to the iSave.
6.9 Drives
6.9.1 Electric motor
The iSave must only be driven by an electric motor.
Using anything other than an electric motor can lead to an irreparable fracture of the
iSave’s internal parts.
6.9.2 Speed control
The rotation speed on the electric motor can be controlled by a VFD.
The direction of rotation can be seen on the identification label.
Checking the direction of rotation can be made by:
1. Looking at the fan in the end of the electric motor.
2. Removing the plug in the bell housing and watch the rotation of coupling.
3. Before assembly the iSave on the electrical motor, check the rotation of the shaft on the
electrical motor.
Special attention has to be on NON PROTECTED – FREE ROTATING shaft on the electrical
motor. Ignorance will or could result in personal injury.
• Running the iSave in the wrong direction for more than a few minutes can cause un-
intended wear on the iSave.
• If the electric motor is running at a lower speed, extra care must be taken to ensure that
the electric motor is NOT overheated. External cooling may be necessary.
6.9.3 Starting torque on the iSave/ramping the electric motor.
Because of the inertia of the iSave internal parts and the fact that the iSave includes a posi-
tive displacement pump, the torque
will
exceed the maximum allowable torque for the
iSave when the speed is not ramped up from zero to maximum.
It is re
quir
ed to use a VFD or a soft starter.
A minimum of 10 seconds is required when ramping up the speed from zero to maximum.
Otherwise, the torque on the iSave will exceed the maximum limit and may lead to an
irreparable fracture of the iSave’s internal parts.
6.9.4 Torque overloads protection on the iSave.
The electric motor and iSave must always be protected against overload.
Both at start-up and at continues operation the maximum torque on the iSave must be
monitored.
Summary of Contents for iSave 21
Page 5: ...User manual iSave 21 5 180R9221 521B1174 DKCFN PS 003 A1 02 1 CE Declaration of conformity...
Page 32: ...User manual iSave 21 32 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 38: ...User manual iSave 21 38 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 43: ...User manual iSave 21 43 180R9221 521B1174 DKCFN PS 003 A1 02 10 3 Data sheet...
Page 44: ...User manual iSave 21 44 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 58: ...User manual iSave 21 58 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 59: ...User manual iSave 21 59 180R9221 521B1174 DKCFN PS 003 A1 02 10 4 iSave part list...
Page 60: ...User manual iSave 21 60 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 61: ...isave danfoss com iSave 21 Parts list 180R9209 DKCFN PC 003 A2 02 Parts list...
Page 66: ...Parts list iSave 21 Parts list 6 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view Vane pump...
Page 68: ...Parts list iSave 21 Parts list 8 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view iSave...
Page 70: ...User manual iSave 21 70 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 71: ...User manual iSave 21 71 180R9221 521B1174 DKCFN PS 003 A1 02 10 5 iSave overload protection...
Page 72: ...User manual iSave 21 72 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 80: ...User manual iSave 21 80 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 82: ...User manual iSave 21 82 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 86: ...User manual iSave 21 86 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 104: ...User manual iSave 21 104 180R9221 521B1174 DKCFN PS 003 A1 02...