9.1 Safety regulations
The operator ensures that all inspection and installation work is performed by authorised,
qualified specialist personnel who are thoroughly familiar with the manual.
Before intervening in the iSave/system;
• The power must be shut off and the starting device be locked.
• The pressure in the High Pressure lines must be drained to Low Pressure side.
• The water in all connected pipes must be drained.
The numbers in () correspond to the preferred system design and P&ID
Problem
Possible cause
Action
VFD can’t start the iSave
at initial start-up.
VFD is not designed for con-
stant torque.
Choose a VFD that is designed
for constant torque.
Ramp-up settings in the VFD is
not correct. VFD is tilting.
Set Ramp-up parameters cor-
rect.
Valve (9) is closed
Open valve (9)
Pressure in the HP line (5) is
too high
Start the iSave only when the
pressure in the HP line is low.
Torque on iSave too
high during operation
Pressure difference from HP-
out (5) to HP-in (10) is too high.
Clean or change membranes.
Debris in the booster pump or
iSave.
Wear in the booster pump or
iSave.
Design of the basic plant
doesn’t fit the performance of
the iSave.
Permeate production is
too low (17).
Valves (6), (7), (8) or (16) are
leaking.
Repair or change valve.
Internal leakage in iSave
Repair iSave
HP pump flow (2) is to small
Incorrect speed on the HP
pump.
Check the HP pump and repair
if necessary.
Pressure on the mem-
branes (5) is too high.
Fouling on the membranes
Clean the membranes
Mixing in the iSave is too high. Check flow on LP-in (12) and
adjust flow.
Flow out of the iSave is too
low, causes a recovery rate
that is too high.
Check speed on iSave and
change if necessary.
Booster pump in the iSave is
worn out.
Perform service on the VP.
Pressure on the mem-
branes (5) is too low.
Valves (6), (7), (8) or (16) are
leaking.
Repair or change valve (s).
Internal leakage in iSave
Repair iSave
HP pump flow (2) is too small
Incorrect speed on the HP
pump.
Check the HP pump and repair
if necessary.
9 Trouble-shooting
Summary of Contents for iSave 21
Page 5: ...User manual iSave 21 5 180R9221 521B1174 DKCFN PS 003 A1 02 1 CE Declaration of conformity...
Page 32: ...User manual iSave 21 32 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 38: ...User manual iSave 21 38 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 43: ...User manual iSave 21 43 180R9221 521B1174 DKCFN PS 003 A1 02 10 3 Data sheet...
Page 44: ...User manual iSave 21 44 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 58: ...User manual iSave 21 58 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 59: ...User manual iSave 21 59 180R9221 521B1174 DKCFN PS 003 A1 02 10 4 iSave part list...
Page 60: ...User manual iSave 21 60 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 61: ...isave danfoss com iSave 21 Parts list 180R9209 DKCFN PC 003 A2 02 Parts list...
Page 66: ...Parts list iSave 21 Parts list 6 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view Vane pump...
Page 68: ...Parts list iSave 21 Parts list 8 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view iSave...
Page 70: ...User manual iSave 21 70 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 71: ...User manual iSave 21 71 180R9221 521B1174 DKCFN PS 003 A1 02 10 5 iSave overload protection...
Page 72: ...User manual iSave 21 72 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 80: ...User manual iSave 21 80 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 82: ...User manual iSave 21 82 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 86: ...User manual iSave 21 86 180R9221 521B1174 DKCFN PS 003 A1 02...
Page 104: ...User manual iSave 21 104 180R9221 521B1174 DKCFN PS 003 A1 02...