Service guide
Disassembling and assembling iSave 40
5
180R9242 | 521B1213 | DKCFN.PI.003.R3.02 | 04.2016
1.
Disassemble the flange for shaft seal.
2.
Wet the shaft seal first with clean filtered
water. Carefully lift the shaft seal by using
2 screwdrivers.
3.
Disassembling the
booster pump
3.
If coupling has to be changed, follow the
next two steps.
4.
Unscrew the 4 coupling bolts. Use a
hammer handle at the opposite end to
prevent the shaft from turning.
5.
Remove coupling and the two pins.
If flange cannot be removed easily, use two
M8 bolts.