Parameter
Unit
Minimum
Continuous
Maximum
Viscosity
mm
2
/sec (cSt) [SUS]
7
[47]
12-60
[70-278]
1600
[7500]
Temperature
°C [°F]
-40 [-40]
82 [180]
104 [220]
Cleanliness
ISO 4406 Class 18/13 or better
Filtration efficiency
suction filtration
β
35-44
=75 (β
10
≥1.5)
charge filtration
β
15-20
=75 (β
10
≥10)
Service Manual
K and L Frame Variable Motors, Cartridge Mount
Technical specifications
©
Danfoss | July 2017
520L0631 | AX00000042en-US0402 | 9