User Guide
MES 1003 WMS
Doc no. 100837-MAN – Rev. E1 – Rev. date 2022-10
© Danfoss IXA A/S | Page 27
Unsigned addresses (2 bytes)
Offset 60
WMS state
AB unsigned value
0
(standby)
1
(starting)
2
(sensing)
3
(stopping)
4
(disconnected)
Table 16: Read Holding Registers – Unsigned
Unsigned integer addresses (4 bytes)
Offset 10006 + Offset
10007
Size of measurement data as specified
by register 10000 and 10002
Integer value AB
10006
AB
10007
Offset 1000 – Offset 1049
WMS part number string
e.g. “1234” represented as 12
1000
34
1001
Offset 1050 – Offset 1099
WMS revision number string
e.g. “1234” represented as 12
1050
34
1051
Offset 1100 – Offset 1149
WMS serial number string
e.g. “1234” represented as 12
1100
34
1101
Offset 1150 – Offset 1199
WMS software revision string
e.g. “2.2.0” represented as 2.
1150
2.
1151
0
1152
Offset 1200 – Offset 1249
WMS OS version string
e.g. “Linux” represented as Li
1200
nu
1201
x
1202
Table 17: Read Holding Registers – Unsigned Integer
All addresses are filled with zeros when requesting more addresses than the string represents, e.g. if the sensor
part number is “1234” and address 1000 – 1002 (3 registers of 2 bytes) is requested, then
Offset
High byte
Low byte
1000
‘1’
‘2’
1001
‘3’
‘4’
1002
0
0