User Guide
MES 1003 WMS
Doc no. 100837-MAN – Rev. E1 – Rev. date 2022-10
© Danfoss IXA A/S | Page 21
2.4.3.
Save Setup
To Save Setup:
1. Insert USB stick
2. Navigate to the Maintenance sub menu
3. Select Save Setup.
The Save Setup function saves the customizations of the WMS to a USB stick. The USB stick can later be used to restore
the same or another WMS to an identical setup. The functionality can be used to create a backup of the WMS settings
before changing some of the parameters available for customization in the LCP. The functionality is also able to carry
customizations between several WMS systems that require identical setups.
2.4.4.
Restore Setup
To Restore Setup:
1. Insert USB stick
2. Navigate to the Maintenance sub menu
3. Select Restore Setup
The Restore Setup function restores the customizations of the WMS to those found on a USB stick. The functionality is
also able to carry customizations between several WMS systems that require identical setups.
2.4.5.
Measurement Log
The measurement log is an important tool to help service personnel analyze the WMS’s behavior. If a query regarding the
WMS’s performance is submitted as in 5.5 Alarms and Troubleshooting, a measurement log may be required to find the
source of technical issues.
Ensure the USB drive is working and is not full, before creating the measurement log.
To create a measurement log:
1. Insert a USB drive
2. Navigate to the measurement info menu
Illustration 29: Measurement info submenu