User Guide
MES 1003 WMS
Doc no. 100837-MAN – Rev. E1 – Rev. date 2022-10
© Danfoss IXA A/S | Page 48
Illustration 82: Saving the calibration
Wait for the calibration to be saved.
Illustration 83: Calibration saved
The calibration has been saved. Press OK to return to the Calibration menu.
5.4.
Verification mode
The system has a verification mode which enables the LCP to show live measurements from all sensors when the
verification mode is activated. These live measurements can be used to verify the measurements from all sensors.
Local Control must be disabled through the LCP. Remember to disable Local Control after verification for Modbus control
to work.
5.4.1.
Activate/deactivate verification mode
The following procedure describes how to activate and deactivate verification mode.
Activate verification mode
To activate verification mode, go to the verification mode menu 6-1*
Illustration 84: Maintenance submenu
Press OK to enter the verification mode menu.
PAH Calibration
6-**
Saving…
PAH Calibration
6-**
Calibration saved
Press OK to return to the
Calibration menu
Maintenance
6-**
6-1*
Verification Mode
6-2*
pH Calibration
6-3*
Turb. Calibration
6-3*
PAH Calibration