Summary of Contents for MPCAN

Page 1: ...User Manual Remote Control MPCAN Receiver www danfoss com...

Page 2: ...revisions Date Changed Rev March 2022 Updated safety instructions and technical descriptions 0201 January 2019 Rebranded to Danfoss Power Solutions 0101 User Manual MPCAN Receiver 2 Danfoss March 202...

Page 3: ...detailed description 7 Installation Receiver installation 9 Input and output configuration 10 STOP category 3 PLe 10 Pinout 11 Troubleshooting MPCAN Receiver Faceplates 12 MPCAN400 900MHz LED troubles...

Page 4: ...e brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement MPCAN General Safety The foll...

Page 5: ...use Always press STOP before plugging in tether cable if applicable Remove the Tether connection on the transmitter First if applicable Do not operate product when visibility is limited Make sure prod...

Page 6: ...MPCAN dimensions Dimensions in mm 15 75 35 99 29 20 133 03 R 3 70 42 27 118 73 101 60 324 52 92 25 User Manual MPCAN Receiver Technical description 6 Danfoss March 2022 BC292573933619en 000201...

Page 7: ...10 Internal fuse 7 5A MPCAN detailed description Technical data Specification Value Stop function 400 900 MHz Cat 3 PLd Stop Function 2 4 GHz Cat 4 PLe Ingress protection IP65 NEMA4 Frequency band ER...

Page 8: ...uts 4 Proportional inputs N A Reponse time 100ms Maximum Total output current 7 5A Operating temperature range 20 C to 70 C 4 F to 158 F Storage Temperature Range 24h 25 C to 75 C 13 F to 167 F Storag...

Page 9: ...is recommended to use an extended antenna in a clear location only for models that allow an antenna In areas of high vibration the use of dampers is advised 7 8 9 10 11 CANL 12 GND 6 5 K4 IN4 4 3 2 C...

Page 10: ...ther at the same time The MPCAN includes a 7 5A internal fuse A1 A7 A8 A6 A5 IN1 IN2 IN3 IN4 Internal Vcc MPCAN STOP category 3 PLe Stop function is performed by two relays in series or parallel A10 a...

Page 11: ...A3 A9 A4 CM NO STOP2 STOP1 NO CM MPCAN pinout 7 8 9 10 11 12 6 5 4 3 2 1 Pin Description 1 Vin 2 CANH 3 KSTOP 2 2 4 KSTOP 1 2 5 K4 IN4 6 K3 IN3 7 K1 IN1 8 K2 IN2 9 KSTOP 1 1 10 KSTOP 2 1 11 CANL 12 G...

Page 12: ...el LED on DATA switched off Radio channel occupied by non Danfoss system Change transmitter s frequency channel DATA Green pulsing Receiving good frames OK ID LED off DATA LED on No valid ID Danfoss s...

Page 13: ...Blue fast pulses System is starting establishing connection with radio and EEPROM Wait Blue continuous Waiting for transmitter communication coming from ACTIVE STOP Release STOP button and press STAR...

Page 14: ...ON N A RELAY Green continuous STOP relay activated N A CANERR Red slow pulses CAN Error physical Layer Verify Connections Red double pulses One expansion has Stopped working Verify Expansion boards R...