CAN interfaces
The device features 2 CAN Bus interfaces. The CAN interfaces meet the specifications CAN 2.0 A/B
protocol and the physical layer according to ISO 11898-2 high-speed up to 1 Mbit / s. The CAN interfaces
are operational only when existing power supply is energized. A support for CAN-FD is not possible.
Device configuration
The CS100 can be remotely configured from the Danfoss PLUS+1® Connect portal to monitor the
machine state, performance, and position. Both position and machine data are periodically transmitted
and stored to the Danfoss Data Portal.
CS100 firmware update
You can load a firmware update to the CS100 via the Danfoss PLUS+1
®
Connect portal. The firmware
update may reset the saved configuration to default. After the firmware update, load your configuration
to the device through the PLUS+1
®
Connect portal.
Secure connection to the PLUS+1 Connect portal
CS100 always establishes a secure encrypted TLS connection to the PLUS+1 Connect portal. If, for specific
reasons, the encryption is a problem, please contact your Danfoss representative for possible solutions.