Digital/analog
Middle range
Description
Unit
Minimum
Typical
Maximum
Comment
Minimum discernible
voltage
V
—
—
0.03
—
Minimum discernible
voltage
V
5.69
5.78
5.88
—
Resolution
mV
—
1.4
—
—
Worst case offset and gain
error
V
—
—
±0.14
V
Measure
= 5.78 V
Non-linearity
mV
—
—
±8.5
—
Input impedance
kΩ
232
233
234
No pull up or pull down
Input impedance (5V/GND) kΩ
13.9
14.1
14.3
Pull up or pull down
Input impedance (2.5V)
kΩ
7.1
7.3
7.4
Pull up and pull down
High range
Description
Unit
Minimum
Typical
Maximum
Comment
Minimum discernible
voltage
V
—
—
0.16
—
Maximum discernible
voltage
V
37.9
38.8
39.7
—
Resolution
mV
—
9.5
—
—
Worst case offset and gain
error
V
—
—
0.95
V
Measure
= 38.8 V
Non-linearity
mV
—
—
±56.8
—
Input impedance
kΩ
109.1
109.3
109.5
No pull up or pull down
(Vin < 5.7 V)
Input impedance (5V/GND) kΩ
13.0
13.2
13.4
Pull up or pull down (Vin <
5.7 V)
Pull up and pull down input
impedance (2.5V)
kΩ
6.9
7.0
7.1
Pull up and pull down (Vin
< 5.7 V)
Multifunction inputs
Low range analog
Description
Unit
Minimum
Typical
Maximum
Comment
Minimum discernible
voltage
mV
—
—
13
—
Maximum discernible
voltage
mV
379
404
430
—
Resolution
mV
—
0.1
—
—
Worst case offset and gain
error
mV
—
—
±0.6
V
Measure
= 404 mV
Non-linearity
mV
—
—
±26
—
Input impedance
kΩ
232
233
234
No pull up or pull down
Input impedance (5V/GND) kΩ
13.9
14.1
14.3
Pull up or pull down
Input impedance (2.5V)
kΩ
7.1
7.3
7.4
Pull up and pull down
Technical Information
PLUS+1 DM1x00 Series Displays
Input/output types and specifications
©
Danfoss | October 2021
BC313277849405en-000204 | 13