CAN shield and analog input
CAN Shield
Description
Unit
Minimum
Typical
Maximum
Comment
Input impedance
—
—
0.68µF+1Ω
—
—
Analog input
Description
Unit
Minimum
Typical
Maximum
Comment
Minimum discernible
voltage
V
—
—
0.03
—
Maximum discernible
voltage
V
5.64
5.78
5.92
—
Resolution
mV
—
1.4
—
—
Worst case offset and gain
error
V
—
—
±0.14
V
Measure
= 5.78 V
Non-linearity
mV
—
—
±8.5
—
Input impedance
kΩ
230
233
236
Digital output
Low side digital output
Description
Unit
Minimum
Typical
Maximum
Comment
Voltage
V
0
—
Vin
Iout = 500mA
Current
mA
0
—
500
—
CAN communication
Description
Unit
Minimum
Typical
Maximum
Comment
Available Baud rates
kbps
50
With 120 Ω termination.
The default baud rate is 250
kbps.
100
125
250
500
1000
Maximum input voltage
range
V
-27
—
40
CAN+ and CAN-
Software updates using CG150 are supported via CAN0 and CAN1 channels.
Technical Information
PLUS+1 DM1x00 Series Displays
Input/output types and specifications
16 |
©
Danfoss | October 2021
BC313277849405en-000204