background image

Supply voltage/maximum current ratings (continued)

Description

Unit

Minimum

Typical

Maximum

Comment

DC supply voltage

V

9

36

Normal operation.

6

Cranking; reduced

functionality.

-36

36

Short circuit and reversed

polarity protection.

DM1000 variants

A

1.7

Vin = 9V

1

Vin = 14V

0.45

Vin = 27V

0.3

Vin = 36V

DM1200 variants

A

2.8

Vin = 9V

1.4

Vin = 14V

0.75

Vin = 27V

0.5

Vin = 36V

+5V output voltage

V

4.75

5

5.09

Normal operation over

temperature.

0

36

Short circuit protection.

+5V output current

mA

100

Short circuit pin voltage

V

0

36

All DEUTSCH connector

pins.

To achieve operation at the lowest supply voltage range, Danfoss has the following recommendations:

1. Use the largest appropriate gauge wire for power and ground to reduce cabling voltage drops.
2. Disable unused peripherals (WiFi, Bluetooth, GNSS, etc).
3. Reduce the overall power requirements on the device.

Reduce the LCD back light intensity.

Reduce the button back light intensity.

Reduce the load on USB Host (C3p03).

Reduce the load on sensor power (C1p08).

Ingress Protection (IP) rating

DM1x00 displays carry Ingress Protection rating of IP66 and IP67 in the front and back.

Technical Information

PLUS+1 DM1x00 Series Displays

Product ratings

 

©

 Danfoss | October 2021

BC313277849405en-000204 | 21

Summary of Contents for PLUS+1 DM1 00 Series

Page 1: ...Technical Information PLUS 1 Mobile Machine Displays DM1x00 Series www danfoss com ...

Page 2: ...tures 0203 December 2020 Corrected Pin Assignment tables 0202 December 2019 Under Pin assignments C1 C9 corrected tables for C5 C6 C7 and C8 and under DM1x00 Series Displays description Dual core 1 2 GHz i MX6 replaced with Dual core 800 MHz i MX6 0201 October 2019 First edition 0101 Technical Information PLUS 1 DM1x00 Series Displays 2 Danfoss October 2021 BC313277849405en 000204 ...

Page 3: ...on inputs 13 CAN shield and analog input 16 Digital output 16 CAN communication 16 USB communication 17 RS232 communication 17 Sensor output 17 Video power 17 Officially validated digital camera formats 17 Officially validated analog camera formats 18 Ethernet 18 Audio outputs 18 Wifi Bluetooth 19 Product ratings DM1x00 environmental testing criteria 20 Supply voltage maximum current ratings 20 In...

Page 4: ... Manual The Operation Manual OM details information regarding the PLUS 1 GUIDE tool used in building PLUS 1 applications This OM covers the following broad topics How to use the PLUS 1 GUIDE graphical application development tool to create machine applications How to configure module input and output parameters How to download PLUS 1 GUIDE applications to target PLUS 1 hardware modules How to uplo...

Page 5: ...aution Unused pins on mating connectors may cause intermittent product performance or premature failure Be sure to plug all pins on mating connectors Display operation guidelines Disconnect your machine s battery power before connecting power and signal cables to the display Before doing any electrical welding on your machine disconnect all power and signal cables connected to the display Do not e...

Page 6: ...g powders or solvents such as alcohol benzene or paint thinner Keep ambient light sensor area clean and uncovered for best operation Danfoss graphical displays are not user serviceable Return the display to the factory in case of failure Technical Information PLUS 1 DM1x00 Series Displays User liability and safety statements 6 Danfoss October 2021 BC313277849405en 000204 ...

Page 7: ...nected to the battery Power the sensors and valve drive circuits by their dedicated wired power sources and ground returns Twist sensor lines about one turn every 10 cm 4 in Use wire harness anchors that will allow wires to float with respect to the machine rather than rigid anchors Machine welding guidelines W Warning High voltage from power and signal cables may cause fire or electrical shock an...

Page 8: ...4 CAN ports RS232 and USB 2 0 high speed Ethernet Bluetooth and WiFi GNSS optional 4 Camera inputs Up to 2 displayed at one time Audio line out Sensor supply out Optional keypad with either 8 buttons on each side 16 total or 8 buttons plus navigation panel 16 total Backlit buttons Touch screen optional Optical signal 2 RGB LEDs Integrated ambient light sensor for automatically adjusting brightness...

Page 9: ...00 Pixels Brightness 900 cd m2 Value includes cover glass Contrast Ratio 500 1 Viewing Angle 85 Degree vertical and horizontal Color Depth 24 Bits 8 bits per color DM1200 LCD 12 1 screen Description Value Unit Notes Screen Size 12 1 Inch Resolution 1280 x 800 Pixels Brightness 900 cd m2 Value includes cover glass Contrast Ratio 500 1 Viewing Angle 85 Degree vertical and horizontal Color Depth 24 B...

Page 10: ...1x8 Navigation Buttons 11223962 DM1000T 0 1 1 0 10 1 Touch 2x8 Buttons WIFI BT GNSS 11223966 DM1000T 0 1 2 0 10 1 Touch 1x8 Navigation Buttons WIFI BT GNSS 11223963 DM1200T 0 0 0 0 12 1 Touch No Buttons 11223964 DM1200T 0 1 0 0 12 1 Touch No Buttons WIFI BT GNSS Mounting kits are not included Please see Related Product section for ordering info Model code A B C D E DM1x00 Model code key A Model na...

Page 11: ...g kit for 10 Display unit with buttons 11224244 Panel mounting kit for 12 Display unit Software 11179523 Annual renewal with 11179524 to keep the software updates PLUS 1 GUIDE Professional Software includes 1 year of software updates a single user license Service and Diagnostic Tool and Screen Editor Connection tools 10100744 DEUTSCH Extraction tool size 20 red 10100745 DEUTSCH solid contacts term...

Page 12: ...kg 5 lb 9 oz DM1200 2 722 kg 6 lb Vibration Shock IEC 60068 2 64 3 17g 2 27 50g EMI RFI rating ISO 13766 Humidity IEC 60068 2 78 60068 2 30 Transients ISO 7637 1 2 3 DM1000 DM1200 FCC Certified Certified CE RED Certified UKCA Certified EAC Certified Giteki Certified RCM Pending E1 Mark Pending Input types Each PLUS 1 Module input pin supports one of the above functional types For pins with multipl...

Page 13: ...e 38 8 V Non linearity mV 56 8 Input impedance kΩ 109 1 109 3 109 5 No pull up or pull down Vin 5 7 V Input impedance 5V GND kΩ 13 0 13 2 13 4 Pull up or pull down Vin 5 7 V Pull up and pull down input impedance 2 5V kΩ 6 9 7 0 7 1 Pull up and pull down Vin 5 7 V Multifunction inputs Low range analog Description Unit Minimum Typical Maximum Comment Minimum discernible voltage mV 13 Maximum discern...

Page 14: ...ND kΩ 13 0 13 2 13 4 Pull up or pull down Vin 5 7 V Input impedance 2 5V kΩ 6 9 7 0 7 1 Pull up and pull down Vin 5 7 V Low range frequency PPU Description Unit Minimum Typical Maximum Comment Range Hz 0 10000 In steps of 1 Hz Rising voltage threshold mV 314 Falling voltage threshold mV 55 Input impedance kΩ 232 233 234 No pull up or pull down Input impedance 5V GND kΩ 13 9 14 1 14 3 Pull up or pu...

Page 15: ...r 7 1 100Ω 2 1 1kΩ 5 4 10kΩ Input impedance Ω 1320 1320 1330 No pull up or pull down Current input 4 20 mA Description Unit Minimum Typical Maximum Comment Minimum discernible current mA 0 12 Maximum discernible current mA 28 2 28 9 29 7 Resolution µA 7 Worst case offset and gain error µA 743 IMeasure 28 9 mA Non linearity µA 42 Input impedance Ω 197 200 202 No pull up or pull down Technical Infor...

Page 16: ...30 233 236 Digital output Low side digital output Description Unit Minimum Typical Maximum Comment Voltage V 0 Vin Iout 500mA Current mA 0 500 CAN communication Description Unit Minimum Typical Maximum Comment Available Baud rates kbps 50 With 120 Ω termination The default baud rate is 250 kbps 100 125 250 500 1000 Maximum input voltage range V 27 40 CAN and CAN Software updates using CG150 are su...

Page 17: ... Unit Minimum Typical Maximum Comment Sensor Output Voltage 5V V 4 85 5 5 15 Sensor Output Voltage 8V V 7 75 8 8 25 Sensor Output Current 5V mA 250 Sensor Output Current 8V mA 150 Video power Description Unit Minimum Typical Maximum Comment Output Voltage 12V V 12 Output Voltage 24V V 24 Output Current 12V mA 750 Output Current 24V mA 375 Officially validated digital camera formats IP Transport Pr...

Page 18: ...5 60 4 433619 Ethernet Symbol Description Unit Minimum Typical Maximum Comment Baud Available baud rates bps 10 M Automatic polarity detection and correction Auto negotiation 100 M Vin Max input voltage range V 25 25 Receiver input Audio outputs Symbol Description Unit Minimum Typical Maximum Comment HP Out Output Power mW 62 5 1kHz Right and left channel included Stereo output Technical Informati...

Page 19: ... 5 2432 2421 2443 44 5220 5210 5230 6 2437 2426 2448 46 5230 5210 5250 7 2442 2431 2453 48 5240 5230 5250 8 2447 2436 2458 9 2452 2441 2463 10 2457 2446 2468 11 2462 2451 2473 Note for the EU region 5GHz U NII 1 band is restricted to in cab applications only Description Unit Minimum Typical Maximum Comment Transmit Power 802 11b dBm 10 5 Transmit Power 802 11g n dBm 11 Transmit Power 802 11a n dBm...

Page 20: ...sions ISO 13766 Electromagnetic compatibility for earth moving machinery EMC immunity ISO 13766 Electromagnetic compatibility for earth moving machinery ESD EN61000 4 2 Electrical transients ISO 7637 2 ISO 7637 3 Short circuit protection Danfoss test Inputs and outputs survive continuous short circuit Normal function resumes when short is removed Reversed polarity protection Danfoss test Survives ...

Page 21: ... 36 All DEUTSCH connector pins To achieve operation at the lowest supply voltage range Danfoss has the following recommendations 1 Use the largest appropriate gauge wire for power and ground to reduce cabling voltage drops 2 Disable unused peripherals WiFi Bluetooth GNSS etc 3 Reduce the overall power requirements on the device Reduce the LCD back light intensity Reduce the button back light inten...

Page 22: ...6 0 26 Flange 60 9 2 40 50 4 1 98 6 6 0 26 Flange 60 9 2 40 50 4 1 98 7 6 0 30 Flange 62 9 2 50 52 4 2 06 294 4 11 60 295 5 11 63 247 2 9 73 1 Light Sensor 2 RGB LED 3 RGB LED 1 Light Sensor 2 RGB LED 3 RGB LED 1 Light Sensor 2 RGB LED 3 RGB LED RAM mount RAM mount RAM mount C5 C4 C3 C9 C6 C7 C8 C2 C1 Button options Standard left and Navigation right button options Technical Information PLUS 1 DM1...

Page 23: ...e 1 Sensor Ground 2 DigOut 3 CAN2 4 CAN2 5 DigIn AnIn CAN Shield 6 CAN3 7 CAN3 8 Multifunction input DigIn AnIn Freq 4 20 mA Rheostat 9 Multifunction input DigIn AnIn Freq 4 20 mA Rheostat 10 Wake Input DigIn 11 DigOut 12 DigOut C3 USB Device M12 4 Pin Male A key Pin Name 1 Device Data 2 Device Data 3 Host Vbus 4 Ground C4 USB Host M12 4 Pin Male D Code Pin Name 1 Host Data 2 Host Data 3 Host Vbus...

Page 24: ...ignal In 2 C7 Video M12 5 Pin A Code Pin Name 1 Pwr Ground 2 Pwr Supply 3 Signal In 3 4 Signal Ground 5 Signal In 4 C8 Ethernet M12 4 Pin D Code Pin Name 1 TxD 2 RxD 3 TxD 4 RxD C9 RS232 Stereo M12 8 Pin A Code Pin Name 1 TxD 2 RxD 3 Ground 4 Manufacturing Use Only Leave Floating 5 Left Channel 6 Right Channel 7 Ground 8 NC Technical Information PLUS 1 DM1x00 Series Displays Installation 24 Danfos...

Page 25: ...panel 3 Panel mounting kit 4 External tooth lock washers x 4 5 Fasting screws 4xM5x0 8 thread type 6 Mounting hole depth 12 mm 0 47 in deep Torque 4 5 N m 39 8 in lbs Panel mounting kit Quantity Description 4 Screws 4 Washers 1 Gasket 1 Bracket Technical Information PLUS 1 DM1x00 Series Displays Installation Danfoss October 2021 BC313277849405en 000204 25 ...

Page 26: ...mount Ram mounting procedure 1 2 3 4 RAM mount parts Call out Description 1 RAM post mount hole pattern 2 Ball size 38 mm 1 5 in Size C 3 External tooth lock washers x 4 4 RAM fastening screws 4xM5x0 8 thread type Mounting hole depth 11 mm 0 43 in deep Torque 4 5 N m 39 8 in lbs Fastening C Caution Use of non recommended screws can cause damage to housing Reassembly with self tapping screws can da...

Page 27: ...letely downloaded flag set and in that case starts to execute it after a delay of 200 ms The delay gives an opportunity for the PLUS 1 Service Tool to prevent the call to the application This allows a non functional application to be replaced by the boot loader This recovery function is activated by the Communication Recover ECU menu in the PLUS 1 Service Tool Cleaning Do not pressure wash Clean u...

Page 28: ...anfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New District Shanghai China 201206 Phone 86 21 2080 6201 Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material Danfoss reserves the right to alter its produ...

Reviews: