Visibility and viewing radius
Due to the display nature of the TFT-LCD screen, the optimal viewing angle for the DM1x00 series
displays are at a maximum radius of 85° from either side of the screen.
Optimal viewing angle
85°
Display faulty application recovery
The boot loader is always executed when the unit is powered. The boot loader checks if the application
has the completely downloaded flag set and in that case starts to execute it after a delay of 200 ms. The
delay gives an opportunity for the PLUS+1
®
Service Tool to prevent the call to the application. This allows
a non functional application to be replaced by the boot loader. This recovery function is activated by the
Communication > Recover ECU menu in the PLUS+1
®
Service Tool.
Cleaning
Do not pressure wash. Clean using a dry, soft, lint-free cloth, such as a micro-fiber cloth.
Technical Information
PLUS+1 DM1x00 Series Displays
Installation
©
Danfoss | October 2021
BC313277849405en-000204 | 27