Application guidelines
6
FRCC.PC.021.A5.22
Compressor features
Liquid injection is controlled by a discharge gas
temperature sensor connected to the OCS.
CAN-Bus connection between manifolded
compressors allows the use of only one HP sensor
and one LP sensor.
A Modbus connection allows the information
exchange between the unit main board (PLC) and
the compressor’s boards (OCS).
Danfoss PSH scroll compressor is optimized for
heat pump applications. Beside scroll elements
pressure ratio optimization, PSH includes 2 major
new technologies: liquid injection and Operating
Control System (OCS).
PSH scroll compressor is also equipped with
several prewired devices such as discharge
temperature sensor, surface sump heater (SSH)
and Liquid Injection Valve (LIV).
Discharge Temperature Sensor
Operating Control System (OCS):
Motor protection
Liquid Injection Valve control
Operating envelope monitoring
Data storage management
Oil surface sump heater control
CAN-Bus/ Modbus Connections
Liquid injection valve (LIV)
Pre-mounted surface sump heater
(SSH) with insulation