background image

Installation guide

Differential thermostat

 

Types RT 270, RT 271 

017

R9

32

3

017

R9

32

3

© Danfoss | DCS (jmn) | 2015.11

IC.PI.P10.T1.53 | 520B6874 | 1

RT 270

Fig. 2

Danfos

s

17-5027.10

Fig. 1

Fig. 3

ENGLISH

Pressure switch
Technical data 

Fig. 1 and 2

Type

Operating 

range for 

LT bulb 

[°C]

Max. 

bulb 

temp. 

[°C]

Mechnical 

contact 

differential

Regulation 

range 

[°C]

RT 270

-30 – 40

65

2

0 – 15

RT 271

20 – 100

200

3

0 – 20

 

Installation

A set of Pg13.5 cable gland is attached to 

the RT in a separate bag. To ensure IP66 

(units with automatic reset) or IP54 (units 

with external reset) grade of RT enclosure 

it is necessary to assemble this gland as 

shown in the fig. 3. If this gland is not used 

with a cable, a metal blinding should be 

also assembled.

Fitting 

Locate the LT bulb (1) in the coldest me-

dium and the HT bulb (32) in the warmest 

medium.

Setting

The differential required between tem-

peratures is set by rotating the nut (5), at 

the same time reading the main scale (9). 

Turning the nut (5) is done most easily with 

a screwdriver.

Example

It is desired to cool a potato store by 

means of ventilation with outside air when 

the outdoor temperature is lower than the 

indoor temperature.

Connect the fan to the RT 270 thermostat 

terminals 1-4. Locate the LT bulb (1) in the 

open, screened against the sun rays, and 

the HT bulb (32) in the store.

Set the thermostat, for example, for a dif-

ferential of 3 °C. The thermostat will then 

start the fan when the outdoor temperature 

is 3 °C + 2 °C = 5 °C lower than the cold 

store temperature. The 2 °C

 

is the contact 

differential. When the difference between 

the outdoor and indoor temperature has 

been reduced to 3 °C, the switch changes 

over, and the fan is cut out.

Pressostater
Tekniske data 

Fig. 1 og 2

Type

LT-føler 

enhedens 

funktions- 

område

[°C]

Max.

føler-

tepe- 

ratur

 

[°C]

Fast 

kontakt-

differens

Indstillings-

område 

[°C]

RT 270

-30 – 40

65

2

0 – 15

RT 271

20 – 100

200

3

0 – 20

 

Montage 

Et sæt Pg13,5 kabelforskruning er vedlagt

produktet i en separat pose. For at sikre

kapslingsgrad IP66 (enheder med automa-

tisk reset) eller IP54 (enheder med ekstern

DANSK

RESET) er det nødvendigt at montere

denne kabelforskruning som vist i fig. 3.

Hvis denne kabelforskruning ikke bruges

sammen med et kabel, bør der monteres

en blindprop (metal skive).

Montering 

Anbring LT-føleren (1) i det koldeste 

medium og HT-føleren (32) i det varmeste.

Indstilling

Den ønskede temperaturdifferens 

indstilles ved at dreje skiven (5) under 

samtidig aflæsning af hovedskalaen (9). 

Skiven (5) drejes lettest med en 

skruetrækker.

Eksempe

Et lagerrum, f.eks. indeholdende kartofler, 

ønskes afkølet ved ventilering med udeluft, 

når udetemperaturen er lavere end 

indetemperaturen.  

Tilslut ventilatoren til RT 270 termostatens 

klemmer 1-4. Anbring LT-føleren (1) i det fri 

skærmet mod solstråler, og HT-føleren (32) 

i lagerrummet.

 

Indstil termostaten på f.eks. 3 °C differens. 

Termostaten vil derpå starte ventilatoren 

når udetemperaturen er 3 °C + 2 °C = 5 °C 

lavere end temperaturen i lagerrummet. 

De 2 °C er kontaktdifferensen. Når forskellen 

mellem ude og indetemperaturen er 

formindsket til 3 °C sker kontaktskifte og 

ventilatoren kobles ud.

Reviews: