Danfoss Heating
7
GB
4.0 Understanding your RZ1
The RZ1 receiver unit uses a combination of coloured LEDs to indicate
the current operating mode/output status. For the purpose of this
document the indicator lights will be split into two distinct groups;
CHANNEL LEDs and PROGRAMME LED. More information is listed
below together with explanations of each of the LED colour states.
Programme
LED
Channel LED
Programme LED
Off
Awaiting Bind/Unbind button press request
Green
Normal Run Mode
Green (slow flash) Factory Reset State
Red
Programme Mode
Red (slow flash)
Binding/association in progress
Orange
Primary controller shift mode enabled
Orange (fast flash) Failed to bind
Channel LED(s) - Programme Mode
Off
Channel Bound/Associated
Red
Channel not Bound/Associated
Red (slow flash)
Channel in process of being
bound/associated
Channel LED(s) - Run Mode
Off
Output OFF
Green
Output ON
Red
Channel not Bound
Red (fast flash)
Channel Bound but no communication
Red (slow flash)
Channel manually overridden to an OFF state
Green/Orange
(slow flash)
Channel manually overridden to an ON state