Danfoss does not take responsibility for incorrect installation or
any frequency interference.
Chance of unintended machine movement on start up.
Ensure the machine is stopped for the entire duration of the
assembly process.
Keep the work area free and wear protective clothing.
Connect the power supply and the output connections using
the connection block diagram provided with the system. The
receiver will enter into scanning mode and show the following:
ORDER
RELAY
ID
DATA
SIGNAL
HARDOK
POWER
CANRUN
CANERR
OFF
ON
BLINKING
LED scanning mode (receiver)
LED
Description
DATA
There is not another system active
in the area
SIGNAL
OFF; channels are signal free
BLINKING; RF signal detected on
the channels
HARDOK
GREEN; Absence of faults on the
boards
POWER
Power supply OK
CANRUN
Communications with expansion
boards are OK
*
*
Only in receivers with CAN connection (except RCAN)
OUT
IN
RF signal detected
Incorrect ID signal from Ikusi system
CORRECT ELEMENTS
Abc
Abc
INCORRECT ELEMENTS -Check
troubleshooting guide
Display scanning mode (receiver)
1. Place a charged battery in the transmitter
2. Turn the contact key
3. Push and pull out the STOP button
The LED of the transmitter will flash orange-green. If the
transmitter has a display, it displays the identification of the
machine, as well as the battery level
4. Press the start button
The green LED should now light indicating the transmitter
is transmitting
5. Turn off the transmitter using the STOP button
ORDER
RELAY
ID
DATA
SIGNAL
HARDOK
POWER
CANRUN
CANERR
OFF
ON
BLINKING
LEDs operational mode (receiver)
OUT
IN
Correct ID (the icon shows the quiality of the link)
Linked state
No Ikusi RF signal detected(the icon shows the
quality)
Incorrect ID ( the icon shows the quality)
Display operational mode (receiver)
Installation Guide
Remote Control
TM70 and Ikontrol
©
Danfoss | January 2019
AI293579926818en-000101 | 1