TP9000
6
GB
PL
GR
ES
GB
IMPORTANT:
The supply to this unit should by wired via a double
pole isolation switch in accordance with BS EN60730-1, i.e. one
which provides air gaps of at least 3mm in both poles of the mains,
and incorporates a 3 amp fuse. It is strongly recommended that solid
conductors be used.
Clearance for
screwdriver
access
Surface fixed cable
bottom entry knockouts
Rear entry
cable access
N &
looping
terminals
Wall or
Plaster box
fitting
Terminal block
Outline of unit
30mm minimum
C/L
!
Thermostat and Remote Room Sensor:
Fix at a height of approximately 1.5m from the fl oor, away from
draughts or heat sources such as radiators, open fi res or direct
sunlight.