GB
PL
DANFOSS HEATING
9
c) Use
+
and
-
keys to scroll backwards and forwards between options
then
V
and
Λ
keys to change the option settings. The fl ashing digit
on the right hand of the display indicates the number of the selected
option. The large characters display the option value selected.
d) To return to
RUN
, press and hold
PROG
until the display returns to
RUN
mde.
Option 30 - Set upper limit of temperature range
This allows the upper limit of the thermostat setting
range to be electronically limited. Press
+
until
Option 30 is displayed, use
V
and
Λ
to select required
setting.
Setting
40 - 5°C (factory setting is 30°C)
Option 31 - Set lower limit of temperature range
This allows the lower limit of the thermostat setting
range to be electronically limited. Press
+
until
Option 31 is displayed, use
V
and
Λ
to select required
setting.
Setting
5 - 40°C (factory setting is 5°C)
Option 32 - Enable Off at lower limit
This enables an
OFF
function to be selected if a set
point below the lower limit is selected. Press
+
until
Option 32 is displayed, use
V
and
Λ
to select required
setting.
Setting 0
Disabled
Setting 1
Enabled (factory setting)
Option 33 - Enable On at upper limit
This enables an
ON
function to be selected if a set
point above the upper limit is selected. Press
+
until
Option 33 is displayed, use
V
and
Λ
to select required
setting.
Setting 0
Disabled (factory setting)
Setting 1
Enabled