8.3.2 Gate Drive Card Mounting Plate
A
1
2
2
3
130BX408
Figure 8.9 Gate Drive Card and Mounting Plate
1
Gate drive card
3
Retaining screw (T-25)
2
Gate drive card mounting plate
Table 8.9
1.
Remove the input terminal mounting plate in
accordance with the procedure.
2.
Disconnect cables from gate drive card
connectors MK100, MK101, and MK106. Note that
cables connected to MK102, MK103, and MK104
can be disconnected easier after removing the
mounting plate part way.
3.
Remove the gate drive card mounting plate by
removing two screws (0.32 in [8 mm]) in the front
of the plate and two screws (0.32 in [8 mm]) at
the back of the plate on the vertical mounting
tabs (not shown). Disconnect cables MK102,
MK103, and MK104.
Reinstall in the reverse order of this procedure. See
for torque tightening values.
8.3.3 Gate Drive Card
1.
Remove the gate drive card mounting plate in
accordance with the procedure.
2.
Remove the gate drive card by removing six
screws (T-25).
Reinstall in the reverse order of this procedure. See
for torque tightening values.