5-12 Terminal 27 Digital Input
Option:
Function:
Select the function from the available digital input range.
No operation
[0]
Reset
[1]
Coast inverse
[2]
Coast and reset inverse
[3]
Quick stop inverse
[4]
DC-brake inverse
[5]
Stop inverse
[6]
Start
[8]
Latched start
[9]
Reversing
[10]
Start reversing
[11]
Enable start forward
[12]
Enable start reverse
[13]
Jog
[14]
Preset ref bit 0
[16]
Preset ref bit 1
[17]
Preset ref bit 2
[18]
Freeze reference
[19]
Freeze output
[20]
Speed up
[21]
Speed down
[22]
Set-up select bit 0
[23]
Set-up select bit 1
[24]
Catch up
[28]
Slow down
[29]
Pulse input
[32]
Ramp bit 0
[34]
Ramp bit 1
[35]
Mains failure inverse
[36]
DigiPot Increase
[55]
DigiPot Decrease
[56]
DigiPot Clear
[57]
Reset Counter A
[62]
Reset Counter B
[65]
1-29 Automatic Motor Adaptation (AMA)
Option:
Function:
The AMA function optimizes dynamic motor performance by au-
tomatically optimizing the advanced motor parameters (par.
1-30 to par. 1-35) at motor standstill.
Activate the AMA function by pressing [Hand on] after selecting
[1] or [2]. See also the section
Automatic Motor Adaptation
. Af-
ter a normal sequence, the display will read: "Press [OK] to
finish AMA". After pressing the [OK] key the frequency converter
is ready for operation.
This parameter cannot be adjusted while the motor is running.
[0]
*
OFF
[1]
Enable complete AMA Performs AMA of the stator resistance R
S
, the rotor resistance
R
r
, the stator leakage reactance X
1
, the rotor leakage reactance
4. How to Programme
VLT
®
Automation Drive FC 300
Operating Instructions High Power
76
MG.33.U1.02 - VLT
®
is a registered Danfoss trademark
4