5.2.21 32-** Motion Control Basic Settings
Par. No. #
Parameter description
Default value
2-set-up
Change during
operation
Conversion
index
Type
32-11
User Unit Denominator
1 N/A
1 set-up
TRUE
0
Uint32
32-12
User Unit Numerator
1 N/A
1 set-up
TRUE
0
Uint32
32-67
Max. Tolerated Position Error
2000000 N/A
1 set-up
TRUE
0
Uint32
32-69
PID Sample Time
16 ms
1 set-up
TRUE
-3
Uint16
32-80
Maximum Allowed Velocity
1500 RPM
1 set-up
FALSE
67
Uint16
32-81
Motion Ctrl Quick Stop Ramp
1000 ms
1 set-up
TRUE
-3
Uint32
5.2.22 33-** Motion Control Adv. Settings
Par. No. #
Parameter description
Default value
2-set-up
Change during
operation
Conversion
index
Type
33-00
Force Home
[0] Home not forced
1 set-up
TRUE
–
Uint8
33-01
Home Offset
0 N/A
1 set-up
TRUE
0
Int32
33-02
Home Ramp Time
10 ms
1 set-up
TRUE
-3
Uint16
33-03
Homing Velocity
100 RPM
1 set-up
TRUE
67
Int16
33-04
Homing Type
[1] Reverse no index
1 set-up
TRUE
–
Uint8
33-41
Negative Software Limit
-500000 N/A
1 set-up
TRUE
0
Int32
33-42
Positive Software Limit
500000 N/A
1 set-up
TRUE
0
Int32
33-43
Negative Software Limit Active
[0] Inactive
1 set-up
TRUE
–
Uint8
33-44
Positive Software Limit Active
[0] Inactive
1 set-up
TRUE
–
Uint8
33-47
Target Position Window
0 N/A
1 set-up
TRUE
0
Uint16
Parameter Lists
VLT
®
AutomationDrive FC 360
140