6.1.3 Start/Stop
Parameters
FC
+24 V
+24 V
D IN
D IN
D IN
COM
D IN
D IN
D IN
D IN
+10
A IN
A IN
COM
A OUT
COM
12
13
18
19
20
27
29
32
33
37
50
53
54
55
42
39
130BB802.10
Function
Setting
Parameter 5-10 T
erminal 18
Digital Input
[8] Start
Parameter 5-12 T
erminal 27
Digital Input
[0] No
operation
Parameter 5-19 T
erminal 37 Safe
Stop
[1] Safe Stop
Alarm
* = Default value
Notes/comments:
If
parameter 5-12 Terminal 27
Digital Input
is set to
[0] No
operation
, a jumper wire to
terminal 27 is not needed.
D IN 37 is an option.
Table 6.7 Start/Stop Command with Safe Stop Option
130BB805.11
Speed
Start (18)
Illustration 6.2 Start/Stop Command with Safe Stop
Parameters
FC
+24 V
+24 V
D IN
D IN
D IN
COM
D IN
D IN
D IN
D IN
+10 V
A IN
A IN
COM
A OUT
COM
12
13
18
19
20
27
29
32
33
37
50
53
54
55
42
39
130BB803.10
Function
Setting
Parameter 5-10 T
erminal 18
Digital Input
[9] Latched
Start
Parameter 5-12 T
erminal 27
Digital Input
[6] Stop
Inverse
* = Default value
Notes/comments:
If
parameter 5-12 Terminal 27
Digital Input
is set to
[0] No
operation
, a jumper wire to
terminal 27 is not needed.
D IN 37 is an option.
Table 6.8 Pulse Start/Stop
Speed
130BB806.10
Latched Start (18)
Stop Inverse (27)
Illustration 6.3 Latched Start/Stop Inverse
Application Set-up Examples
Operating Instructions
MG33AQ02