8.1.4 Mains Supply 525–690 V (FC 302 only)
Type designation
P1K1
P1K5
P2K2
P3K0
P4K0
P5K5
P7K5
High/normal overload
1)
HO/NO
HO/NO
HO/NO
HO/NO
HO/NO
HO/NO
HO/NO
Typical shaft output (kW)
1.1
1.5
2.2
3.0
4.0
5.5
7.5
Enclosure protection rating IP20
A3
A3
A3
A3
A3
A3
A3
Output current
Continuous (525–550 V) [A]
2.1
2.7
3.9
4.9
6.1
9.0
11.0
Intermittent (525–550 V) [A]
3.4
4.3
6.2
7.8
9.8
14.4
17.6
Continuous (551–690 V) [A]
1.6
2.2
3.2
4.5
5.5
7.5
10.0
Intermittent (551–690 V) [A]
2.6
3.5
5.1
7.2
8.8
12.0
16.0
Continuous kVA 525 V
1.9
2.5
3.5
4.5
5.5
8.2
10.0
Continuous kVA 690 V
1.9
2.6
3.8
5.4
6.6
9.0
12.0
Maximum input current
Continuous (525–550 V) [A]
1.9
2.4
3.5
4.4
5.5
8.1
9.9
Intermittent (525–550 V) [A]
3.0
3.9
5.6
7.0
8.8
12.9
15.8
Continuous (551–690 V) [A]
1.4
2.0
2.9
4.0
4.9
6.7
9.0
Intermittent (551–690 V) [A]
2.3
3.2
4.6
6.5
7.9
10.8
14.4
Additional specifications
Maximum cable cross-section
2)
for mains, motor, brake,
and load sharing [mm
2
] ([AWG])
4, 4, 4 (12, 12, 12) (minimum 0.2 (24)
Maximum cable cross-section
2)
for disconnect [mm
2
]
([AWG])
6, 4, 4 (10, 12, 12)
Estimated power loss at rated maximum load (W)
3)
44
60
88
120
160
220
300
Efficiency
4)
0.96
0.96
0.96
0.96
0.96
0.96
0.96
Table 8.10 A3 Enclosure, Mains Supply 525–690 V IP20/Protected Chassis, P1K1–P7K5
Type designation
P11K
P15K
P18K
P22K
High/normal overload
1)
HO
NO
HO
NO
HO
NO
HO
NO
Typical shaft output at 550 V [kW]
7.5
11
11
15
15
18.5
18.5
22
Typical shaft output at 690 V [kW]
11
15
15
18.5
18.5
22
22
30
Enclosure protection rating IP20
B4
B4
B4
B4
Enclosure protection rating IP21, IP55
B2
B2
B2
B2
Output current
Continuous (525–550 V) [A]
14.0
19.0
19.0
23.0
23.0
28.0
28.0
36.0
Intermittent (60 s overload) (525–550 V) [A]
22.4
20.9
30.4
25.3
36.8
30.8
44.8
39.6
Continuous (551–690 V) [A]
13.0
18.0
18.0
22.0
22.0
27.0
27.0
34.0
Intermittent (60 s overload) (551–690 V) [A]
20.8
19.8
28.8
24.2
35.2
29.7
43.2
37.4
Continuous kVA (at 550 V) [kVA]
13.3
18.1
18.1
21.9
21.9
26.7
26.7
34.3
Continuous kVA (at 690 V) [kVA]
15.5
21.5
21.5
26.3
26.3
32.3
32.3
40.6
Maximum input current
Continuous (at 550 V) (A)
15.0
19.5
19.5
24.0
24.0
29.0
29.0
36.0
Intermittent (60 s overload) (at 550 V) (A)
23.2
21.5
31.2
26.4
38.4
31.9
46.4
39.6
Continuous (at 690 V) (A)
14.5
19.5
19.5
24.0
24.0
29.0
29.0
36.0
Intermittent (60 s overload) (at 690 V) (A)
23.2
21.5
31.2
26.4
38.4
31.9
46.4
39.6
Additional specifications
Maximum cable cross-section
2)
for mains/motor,
load share, and brake [mm
2
] ([AWG])
35, 25, 25 (2, 4, 4)
Maximum cable cross-section
2)
for mains disconnect
[mm
2
] ([AWG])
16, 10, 10 (6, 8, 8)
Estimated power loss at rated maximum load (W)
3)
150
220
220
300
300
370
370
440
Efficiency
4)
0.98
0.98
0.98
0.98
Table 8.11 B2/B4 Enclosure, Mains Supply 525–690 V IP20/IP21/IP55 - Chassis/NEMA 1/NEMA 12 (FC 302 only), P11K–P22K
Specifications
VLT
®
AutomationDrive FC 301/302
58
Danfoss A/S © 07/2015 All rights reserved.
MG33AQ02
8
8
Summary of Contents for VLT AutomationDrive FC 301
Page 2: ......