3 Product Overview
3.1 Intended Use
The drive is an electronic motor controller that converts AC mains input into a variable AC waveform output. The frequency
and voltage of the output are regulated to control the motor speed or torque. The drive is designed to:
•
Regulate motor speed in response to system feedback or to remote commands from external controllers.
•
Monitor system and motor status.
•
Provide motor overload protection.
The drive is designed for industrial and commercial environments in accordance with local laws and standards. Depending
on configuration, the drive can be used in standalone applications or form part of a larger system or installation.
NOTICE
In a residential environment, this product can cause radio interference, in which case supplementary mitigation
measures can be required.
Foreseeable misuse
Do not use the drive in applications which are non-compliant with specified operating conditions and environments. Ensure
compliance with the conditions specified in
.
3.2 Power Ratings, Weights, and Dimensions
For enclosure sizes and power ratings of the drives, refer to
. For more dimensions, see
Enclosure size
J8
J9
IP
NEMA
20
Chassis
20
Chassis
Shipping dimensions [mm (in)]
Height
587 (23)
587 (23)
Width
1230 (48)
1430 (56)
Depth
460 (18)
535 (21)
Drive dimensions [mm (in)]
Height
1026.5 (40.4)
1293.78 (50.9)
Width
250.0 (9.8)
350.0 (13.8)
Depth
375.0 (14.8)
375.0 (14.8)
Maximum weight [kg (lb)]
101.2 (223.1)
168.6 (376.1)
Table 3.1 Power Ratings, Weight, and Dimensions, Enclosure Sizes J8–J9, 380–480 V
Product Overview
VLT® AutomationDrive FC 361
6
Danfoss A/S © 06/2018 All rights reserved.
MG06I102
3