5.2 Type Code String
Example of Drive Configurator interface setup: The numbers shown in the boxes refer to the letter/figure number of the
Type Code String - read from left to right.
Product
Name
Position
Selection options
FCM 106
FCP 106
Product Group
1-3
FCP
FCM
Series
4-6
106
Power size
7-10
0.55-7.5 kW (PK55 - P7K5)
Mains voltage
11-12
T4: 380-480 V AC
Enclosure
13-15
C66: IP 66/UL TYPE 4X (FCP 106 only)
C55: IP 55/NEMA 12 (FCM 106 only)
RFI filter
16-17
H1: RFI filter Class C1
Fan option
18
F: with fan
Special version
19-21
SXX: Latest release - std. Software
Options
22-23
AX: no option
AN: Memory module, without fieldbus
a)
AM: Memory module, Profibus DP V1
a)
Not assigned
24
X: Reserved
Motor range
25
E: Standard motor range
Efficiency class
26
2: Motor Efficiency IE2
4: Motor Efficiency IE4
Load profile
27
N: Normal overload
H: High overload
Shaft power
28-30
0.55-7.5 kW (K55-7K5)
Nominal motor speed
31-33
150: 1500 RPM
180: 1800 RPM
300: 3000 RPM
360: 3600 RPM
Motor mounting option
34-36
B03: Foot mounting
B05: B5 flange
B14: B14 Face
B34: Foot and B14 face
B35: Foot and B5 flange
Motor flange
37-39
000: Foot mounting only
085: Motor flange size 85 mm
100: Motor flange size 100 mm
115: Motor flange size 115 mm
130: Motor flange size 130 mm
165: Motor flange size 165 mm
215: Motor flange size 215 mm
265: Motor flange size 265 mm
300: Motor flange size 300 mm
350: Motor flange size 350 mm
Table 5.1 Type Code Specification
a) Available for future release
Type Code and Selection Gui...
VLT
®
DriveMotor FCP 106 and FCM 106 Design Guide
44
MG03M102 -
08/2015
5
5
Summary of Contents for VLT DriveMotor FCM 106
Page 2: ......