In operation block
Startup [OB100]
, check that the module access points have been allocated correctly:
Expand
Program blocks
in the
Devices
tab.
Double-click on
Startup [OB100]
.
Type the settings in the screenshot ensuring that the module access points names match the name assigned automati-
cally by TIA. These can be found by opening menu [PLC tags
→
Show all tags] and then selecting the
System constants
tab.
e3
0b
i2
62
.1
0
Define the input and output telegram address for each system component by creating a tag table:
Select menu [PLC tags
→
FlexMotion], to open the FlexMotion_Telegram window.
Define the address of the incoming and outgoing telegram for each system component.
e3
0b
i2
63
.1
0
In operation block
Synchronous Cycle [OB61]
, enter the telegram read instructions as per the example below.
AQ262449648484en-000101 / 175R1135 | 129
Danfoss A/S © 2020.08
Commissioning
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide