Table 51: AUX user limit current (0x2393 / 0x127)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x2393 0x127
AUX user limit
current
Error
Current on the AUX line has reached
the user-defined limit for fault.
AUX curr limit
9.3.12 AUX user limit current warning (0x2394 / 0x128)
This error is valid for PSM 510 and DAM 510.
Table 52: AUX user limit current warning (0x2394 / 0x128)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x2394 0x128
AUX user limit cur-
rent warning
Warning
Current on the AUX line has reached
the user-defined limit for warning.
AUX curr
warn
9.3.13 AUX supply failure (0x2395 / 0x129)
This error is valid for DAM 510.
Table 53: AUX supply failure (0x2395 / 0x129)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0x2395 0x129
AUX supply fail-
ure
Error
AUX supply failure indicated by
hardware circuit..
AUX supply fail
9.3.14 Current overload trip (0x2396 / 0x15C)
This error is valid for DAM 510 and ISD 510/DSD 510.
Table 54: Current overload trip (0x2396 / 0x15C)
Code
PROFINET
®
code Name
Severity (warning/error/trip
lock)
Description
LCP name
0x2396 0x15C
Current overload
trip
Error
Current overload trip error. curr ovld trip
9.3.15 Power overload trip (0x2397 / 0x12B)
This error is valid for PSM 510.
Table 55: Power overload trip (0x2397 / 0x12B)
Code
PROFINET
®
code Name
Severity (warning/error/trip
lock)
Description
LCP name
0x2397 0x12B
Power overload trip Error
Power overload trip error. pwr ovld trip
9.3.16 Thermal overload motor (0x239B / 0x102)
This error is valid for ISD 510/DSD 510.
Table 56: Thermal overload motor (0x239B / 0x102)
Code
PROFINET
®
code Name
Severity (warning/error/trip
lock)
Description
LCP name
0x239B 0x102
Thermal overload
motor
Warning, error
Thermal overload motor
error.
therm ovld mo-
tor
AQ262449648484en-000101 / 175R1135 | 163
Danfoss A/S © 2020.08
Diagnostics
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide