Table 110: Firmware: Package description mismatch (0xFF70 / 0x11B)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0xFF70 0x11B
Firmware: Package de-
scription mismatch
Trip lock
The firmware found does not
match the package description.
FW pack err
9.3.71 Firmware: Power cycle needed (0xFF71 / 0x11C)
This error is valid for PSM 510, DAM 510, ACM 510, and ISD 510/DSD 510.
Table 111: Firmware: Power cycle needed (0xFF71 / 0x11C)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0xFF71 0x11C
Firmware: Pow-
er cycle needed
Warning, error
The firmware update transfer is completed
but a power cycle is required before the
new firmware is active.
need power-
cycle
9.3.72 Firmware: Update started (0xFF72 / 0x11D)
This error is valid for PSM 510, DAM 510, ACM 510, and ISD 510/DSD 510.
Table 112: Firmware: Update started (0xFF72 / 0x11D)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0xFF72 0x11D
Firmware: Up-
date started
Warning, error
Firmware update is in progress.
Warning changes to error when an attempt is
made to enable the device in this state.
FW update
9.3.73 Firmware: Update invalid (0xFF73 / 0x15B)
This error is valid for PSM 510 and DAM 510.
Table 113: Firmware: Update invalid (0xFF73 / 0x15B)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0xFF73 0x15B
Firmware: Up-
date invalid
Error
Invalid or corrupted firmware package
update.
Last valid firmware package has been loa-
ded.
FW upd invalid
9.3.74 STO active while drive enabled (0xFF80 / 0x11E)
This error is valid for ISD 510/DSD 510.
Table 114: STO active while drive enabled (0xFF80 / 0x11E)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0xFF80 0x11E
STO active while
drive enabled
Error
STO activated while drive was enabled
or tried to enable while STO active.
STO active
9.3.75 STO mismatch (0xFF81 / 0x11F)
This error is valid for ISD 510/DSD 510.
AQ262449648484en-000101 / 175R1135
174 | Danfoss A/S © 2020.08
Diagnostics
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide