Definition
Unit
Power size 1
Power size 2
Power size 3
Mounting
–
Wall-mounted on backplate using backlink connector
Weight
kg
6
Dimensions (W x H x D)
mm
137.3 x 406.3 x 270
1
An external brake resistor can be connected.
11.2.5 Characteristic Data for Decentral Access Module (DAM 510)
Table 125: Characteristic Data for DAM 510
Definition
Unit
Power size 1
Power size 2
Input
DC-link
V DC
565–680 ±10%
DC-link capacitance
µF
660
Maximum input current
A DC
15
24
U
AUX
V DC
24/48 ±10%
U
AUX
current consumption at 24 V DC
A DC
0.5
U
AUX
current consumption at 48 V DC
A DC
0.3
Output
Output voltage
V DC
V
OUT
PSM
Output current DC-link
A DC
15
25
Peak current DC-link (rms value) t <1.0 s
A
rms
30 for <1 s
48 for <1 s
Output current U
AUX
A DC
15
General
Protective measures
–
Overload, short-circuit, and ground fault protection
Cooling
–
Natural convection
Mounting
–
Wall-mounted on backplate using backlink connector
Weight
kg
3.05
Dimensions (W x H x D)
mm
84.3 x 471 x 270
11.2.6 Characteristic Data for Auxiliary Capacitors Module (ACM 510)
Table 126: Characteristic Data for ACM 510
Definition
Unit
Value
DC-link
V DC
565–680 ±10%
DC-link capacitance
µF
2750
U
AUX
V DC
24/48 ±10%
U
AUX
current consumption at 24 V DC
A DC
0.5
AQ262449648484en-000101 / 175R1135
190 | Danfoss A/S © 2020.08
Specifications
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide