Illustration 19: Minimum Distance for M23 Straight Connector
4.7.1.2 Minimum Distance for M23 Angled Connector on ISD 510
The minimum distance for the angled connector is calculated as follows:
0.5 x cable di connector length measured from electronic h R
min
= 7.8 mm + 51.4 mm + 78 mm = 137.8 mm ≈
140 mm
51.4
[2.02]
[5.51]
Rmin
65
.5
[2
.5
7]
80 [3.
14
]
140 min
e3
0b
f9
51
.1
0
Illustration 20: Minimum Distance for M23 Angled Connector
4.7.2 Space Requirements for DSD 510 Servo Drive
In addition to its own dimensions, the DSD 510 servo drive needs space for the hybrid cable.
4.7.2.1 Minimum Distance for M23 Straight Connector on DSD 510
shows the straight connector installed on a DSD 510 servo drive.
4.7.2.2 Minimum Distance for M23 Angled Connector on DSD 510
shows the angled connector installed on a DSD 510 servo drive.
The illustrations show the minimum distance from the servo drive to the next object, and the minimum allowable bending radius
R
min
for permanently installed cable. For cable installation, allow the height of the connector plus an additional 30 mm for the cable.