Table 88: External brake chopper overload (0x7182 / 0x143)
Code
PROFI-
NET
®
code
Name
Severity (warn-
ing/error/trip
lock)
Description
LCP name
0x7182 0x143
External
brake chop-
per over-
load
Warning, error
The power load of the brake chopper is monitored during
operation.
Depending on the configuration of
external brake chopper
power monitoring
this warning or fault appears when the
configured nominal external brake chopper power is
reached.
ext brake
ch ovl
9.3.49 Brake mains voltage too high (0x7183 / 0x159)
This error is valid for PSM 510.
Table 89: Brake mains voltage too high (0x7183 / 0x159)
Code
PROFINET
®
code
Name
Severity (warn-
ing/error/trip
lock)
Description
LCP name
0x7183 0x159
Brake mains
voltage too
high
Warning
The mains voltage is too high.Due to this, the brake
chopper could be activated continuously depending
on the value entered in parameter
brake chopper start
level
.
brake ch
high volt
9.3.50 Internal position sensor error (0x7320 / 0x10C)
This error is valid for ISD 510/DSD 510.
Table 90: Internal position sensor error (0x7320 / 0x10C)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0x7320 0x10C
Internal position sensor
error
Trip lock
Absolute position sensor er-
ror.
int sensor err
9.3.51 External position sensor error (0x7380 / 0x10D)
This error is valid for DAM 510 and ISD 510/DSD 510.
Table 91: External position sensor error (0x7380 / 0x10D)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x7380 0x10D
External position sensor
error
Error
External encoder data could
not be read.
ext sensor err
9.3.52 Following error (0x8611 / 0x10E)
This error is valid for ISD 510/DSD 510.
Table 92: Following error (0x8611 / 0x10E)
Code
PROFINET
®
code Name
Severity (warning/error/trip
lock)
Description
LCP name
0x8611 0x10E
Following error Warning, error
A following error has occurred. following err
AQ262449648484en-000101 / 175R1135
170 | Danfoss A/S © 2020.08
Diagnostics
VLT® Servo Drive System ISD 510/DSD 510