e
3
0
b
g
4
5
9
.1
0
Illustration 145: U
AUX
Connector
Table 139: Pin Assignment of U
AUX
Connector
Pins
(left to
right)
De-
scrip-
tion
Notes
Rating/parameter
1
24 V
AUX
Used for 24–48 V DC in-
put to the Power Supply
Module (PSM 510).
Nominal input voltage: 24 V/48 V DC ±10%
Nominal current: Depends on the number of servo drives in the application.
Maximum current: 50 A
Maximum cross-section: 16 mm
2
Maximum cable length: 3 m
Conductor cross-section range 0.75–16 mm
2
, solid or flexible (AWG 18–AWG 4)
2
GND
N O T I C E
Only PELV potential can be connected to the U
AUX
input.
11.9.5.1 24/48 V Cable Cross Sections for PSM 510
Minimum cable cross section for CE (minimum 70 °C, Cu)
16 mm
2
Minimum cable cross section for UL (minimum 60 °C, Cu)
4 AWG
11.9.6 LCP Connector (M8, 6-pole)
The LCP connector is located on the front of all the system modules. It used to connect the LCP directly via a cable.
e
3
0
b
e
4
3
4
.1
0
1
2
3
4
5
6
Illustration 146: LCP Connector (M8, 6 pole)
Table 140: Pin Assignment of LCP Connector
Pins
Description
Notes
Rating/parameter
1
Not connected
–
–
2
/LCP RST
Reset
Active at
≦
0.5 V
3
LCP RS485
Positive RS485 signal
Speed:
38.4 kBd
The levels fulfill the RS485 specification.
4
/LCP RS485
Negative RS485 signal
AQ262449648484en-000101 / 175R1135
206 | Danfoss A/S © 2020.08
Specifications
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide