e
3
0
b
g
4
5
6
.1
0
Illustration 155: AUX Connector
Table 148: Pin Assignment of AUX Connector
Pins
(left to
right)
Description Notes
Rating/parameter
1
AUX+
(24/48 V)
Used to connect the AUX output
from the Decentral access Module
(DAM 510) to the hybrid cable for
the servo drive line.
Nominal voltage: 24/48 V DC ±10%
Nominal current: Depends on the number of servo drives in the
application.
Maximum current: 15 A
Conductor cross-section range: 0.2–2.5 mm
2
(AWG 24–AWG 12)
Plug terminal tightening torque: 0.5–0.6 Nm
2
AUX– (GND)
N O T I C E
Only PELV potential can be connected to the AUX output.
11.9.12 External Encoder Connectors
This connector is used to connect an external encoder to DAM 510. It provides a guide value for CAM mode and Gear mode.The
external encoder connector is located on the Decentral Access Module (DAM 510) as follows:
DAM 510: E DAM
5
1
6
9
e3
0b
g4
61
.1
0
Illustration 156: External Encoder Connector
Table 149: External Encoder Connectors
Connector
name
Description
Pins
Ratings/Notes
E DAM
Used to connect the ex-
ternal encoder to
DAM 510.
See
Nominal voltage: 24 V DC, isolated (see
)
Nominal current: Depends on the number of servo drives in the applica-
tion.
Maximum current: 150 mA (see
Fulfill the following specifications:
BISS/SSI
AQ262449648484en-000101 / 175R1135
212 | Danfoss A/S © 2020.08
Specifications
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide