11.10.2 System Modules
Table 154: General Specifications and Environmental Conditions for System Modules
Specification
Value
Protection rating
IP20 according to IEC/EN 60529 (except connectors, which are IP00).
W A R N I N G
RISK OF ELECTRICAL SHOCK
The IP20 rating of the PSM 510, DAM 510, and ACM 510 modules is not fulfilled if
the modules are not connected to the backplate. This may result in death or seri-
ous injury.
Do not touch the backplate when a module is removed from the backplate.
Vibration test
Random vibration: 1.14 g (2h/axis according to EN 60068-2-64)
Sinusoidal vibration: 1.0 g (2h/axis according to EN 60068-2-6)
Maximum relative humidity
Storage/transport: 5–95% (non-condensing)
Stationary use: 5–93% (non-condensing)
Ambient temperature range
Operating: 5–40 °C nominal, up to 55 °C with derating (see
)
Transport: –25 to +55 °C
Storage: –25 to +55 °C
Installation altitude
Nominal current up to 1000 m above sea level.
Derating of output current (1% / 100 m) from 1000 m to 3000 m.
Operation above 3000 m is not permitted.
EMC standard for emission and immunity
EN 61800-3
EMC immunity for functional safety
EN 61800-5-2 Annex E
Degree of pollution according to EN
60664-1
2
Overvoltage category according to
EN/IEC 61800-5-1
III
O
u
tp
u
t
cu
rr
e
n
t
[%
]
100
90
80
70
60
30
35
40
45
50
55
e
3
0
b
h
1
0
6
.1
0
Illustration 158: Derating