3.8 Local Control Panel (LCP)
3.8.1 Overview of the Local Control Panel
The LCP is the graphical user interface that can be connected to the PSM 510, DAM 510, and ACM 510 for diagnostic and operating
purposes using an optional cable (M8 to LCP D-SUB extension cable). The LCP is available as an option and can also be connected to
the advanced version servo drives using the same optional cable.
The LCP display provides the operator with a quick view of the state of the ISD 510/DSD 510 servo drive or module, depending on
which device it is connected to. The display shows parameters and alarms/errors and can be used for commissioning and trouble-
shooting. It can also be used to perform simple functions, for example activating and deactivating the output lines on the Decentral
Access Module.
The LCP can be mounted on the front of the control cabinet and then connected to the modules via SUB-D cables.
3.8.2 Layout of the Local Control Panel
The local control panel is divided into 4 functional groups:
A: Display area
B: Display menu keys
C: Navigation keys and indicator lights (LEDs)
D: Operation keys and reset
To adjust the display contrast, press [Status] and the [
▵
]/[
▿
] keys.
3.8.2.1 A: Display area
The values in the display area differ depending on whether the LCP is connected to a Danfoss servo drive or system module.
The display area is activated when the servo drive or module it is connected to receives power from the mains supply, a DC bus
terminal, or U
AUX
.
Auto
On
Reset
Hand
On
Off
Status
Quick
Menu
Main
Menu
Alarm
Log
B
ac
k
Ca
nc
el
In
fo
OK
Status
271°
2850 RPM
On
Alarm
Warn.
A
38 °C
3.1 Nm
B
C
D
1.8 A
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
e
3
0
b
e
6
9
2
.1
2
Illustration 8: Display Area when Connected to an ISD 510 Servo Drive
1
Actual torque
2
Temperature drive module
AQ262449648484en-000101 / 175R1135 | 37
Danfoss A/S © 2020.08
System Description
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide