Table 50: UAUX charging error (0x3297 / 0x154)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x3297 0x154
U
AUX
charging
error
Error
Load error when U
AUX
is charging. The maxi-
mum time limit to charge the AUX line has
been exceeded.
UAUX charg
err
9.4.25 DC link shutdown error (0x3298 / 0x165)
This error is valid for DAM 510.
Table 51: DC link shutdown error (0x3298 / 0x165)
Code
PROFINET
®
code Name
Severity (warning/error/
trip lock)
Description
LCP name
0x3298 0x165
DC link shutdown
error
Error
Error when UDC is in shut-
down phase.
UDC shutdwn err
9.4.26 UAUX shutdown error (0x3299 / 0x155)
This error is valid for DAM 510.
Table 52: UAUX shutdown error (0x3299 / 0x155)
Code
PROFINET
®
code Name
Severity (warning/error/
trip lock)
Description
LCP name
0x3299 0x155
U
AUX
shutdown
error
Error
Error when U
AUX
is in shut-
down phase.
UAUX shtdwn
err
9.4.27 UAUX undervoltage hardware (0x329A / 0x156)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 53: UAUX undervoltage hardware (0x329A / 0x156)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x329A 0x156
U
AUX
undervoltage
hardware
Error
U
AUX
undervoltage detected by
hardware circuit.
AUX undervol
HW
9.4.28 Automated fault reset failure (0x329B / 0x168)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 54: Automated fault reset failure (0x329B / 0x168)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x329B 0x168
Automated fault re-
set failure
Trip lock
Too many auto fault resets have been
executed in intended time interval.
autoreset fail
9.4.29 Device overtemperature (0x4210 / 0x157)
This error is valid for PSM 510, DAM 510, ACM 510, and ISD 511.
AQ377148425069en-000101
/ 130R1213
106 | Danfoss A/S © 2023.08
Diagnostics
VLT® Servo Drive System ISD 511
Operating Guide