e30bg459.10
Illustration 81: U
AUX
Connector
Table 121: Pin Assignment of U
AUX
Connector
Pins
(left to
right)
Descrip-
tion
Notes
Rating/parameter
1
24 V AUX Used for 24–48 V DC input to
the Power Supply Module
(PSM 510).
Nominal input voltage: 24 V/48 V DC ±10%
Maximum current: 50 A
Maximum cross-section: 16 mm
2
Maximum cable length: 3 m
Conductor cross-section range 0.75–16 mm
2
, solid or flexible (AWG 18–
AWG 4)
2
GND
N O T I C E
Only PELV potential can be connected to the U
AUX
input.
C A U T I O N
POSSIBLE LOSS OF FUNCTIONAL SAFETY PROTECTION
The functional safety feature may be affected if the U
AUX
input exceeds 60 V.
Ensure that the U
AUX
input remains below 60 V.
11.6.5.1 24/48 V Cable Cross-Sections for PSM 510
Minimum cable cross-section for CE (minimum 70 °C, Cu)
16 mm
2
Minimum cable cross-section for UL (minimum 60 °C, Cu)
4 AWG
11.6.6 LCP Connector (M8, 6-pole)
There is an LCP connector on the front of all the system modules. It is used to connect the LCP directly via a cable.
e30be434.10
1
2
3
4
5
6
Illustration 82: LCP Connector (M8, 6 pole)
AQ377148425069en-000101
/ 130R1213 | 139
Danfoss A/S © 2023.08
Specifications
VLT® Servo Drive System ISD 511
Operating Guide