5.4.15 Conversion of Parameter 342 Term. 46, Max. Pulse Scaling
Table 106: Parameter 342
FCD 300 series
FCD 302 series
Parameter
342 Term. 46, Max. Pulse Scaling
5-65 Pulse Output Max Freq. #29
Range
150–10000 Hz
0–32000 Hz
5.4.16 Conversion of Parameter 343 Precise Stop Function
Table 107: Parameter 343
FCD 300 series
FCD 302 series
Parameter
343 Precise Stop Function
1-83 Precise Stop Function
Options
[0] Normal
[0] Precise Ramp Stop
[1] Count Stop Reset
[1] Cnt Stop With Reset
[2] Count Stop No Reset
[2] Cnt Stop W/O Reset
[3] Spd Cmp Cstop
[3] Speed Comp Stop
[4] Spd Cmp Cstop W. Reset
[4] Cnt Stop W/Rst
[5] Spd Cmp Cstop No Reset
[5] Comp Cnt Stop W/O Reset
5.4.17 Conversion of Parameter 344 Counter Value
Table 108: Parameter 344
FCD 300 series
FCD 302 series
Parameter
344 Counter Value
1-84 Precise Stop Counter Value
Range
0–999999
0–999999999
5.4.18 Conversion of Parameter 349 Speed Compensated Delay
Table 109: Parameter 349
FCD 300 series
FCD 302 series
Parameter
349 Speed Compensated Delay
1-85 Precise Stop Speed Compensation Delay
Range
0–100 ms
0–100 ms
Parameter Mapping Lists
Operating Guide | VLT® FCD 300 PROFIBUS Converter MCA 117
AQ289550754901en-000101 / 130R0890| 55
Danfoss A/S © 2019.11