16-9* Diagnosis Readouts
16-90 Alarm Word
0-0XFFFFFFFF
16-92 Warning Word
0-0XFFFFFFFF
16-94 Ext. Status Word
0-0XFFFFFFFF
18-** Extended Motor Data
18-8* Motor Resistors
18-80 Stator Resistance (High
resolution)
0.000-99.990 ohm *0.000 ohm
18-81 Stator Leakage Reactance
(High resolution)
0.000-99.990 ohm *0.000 ohm
Table 5.5
5.1.1 Conversion Index
The various attributes of each parameter are displayed in
the section
Factory Settings
. Parameter values are
transferred as whole numbers only. Conversion factors are
therefore used to transfer decimals according to
Table 5.6
.
Example:
1-24 Motor Current
has a conversion index of -2 (i.e.
conversion factor of 0.01 according to
Table 5.6
). To set the
parameter to 2.25 A, transfer the value 225 via Modbus.
The Conversion Factor of 0.01 means that the value
transferred is multiplied by 0.01 in the frequency converter.
The vale 225 transferred on the bus is thus perceived as
2.25 A in the frequency converter.
Conversion index
Conversion factor
2
10
1
100
0
1
-1
0.1
-2
0.01
-3
0.001
-4
0.0001
-5
0.00001
Table 5.6 Conversion Table
5.1.2 Change during operation
“TRUE” means that the parameter can be changed while
the frequency converter is in operation and “FALSE” means
that the frequency converter must be stopped before a
change can be made.
5.1.3 2-Set-up
“All set-up”: The parameter can be set individually in each
of the two set-ups, i.e. one single parameter can have two
different data values.
”1 set-up”: Data value will be the same in both set-ups.
5.1.4 Type
Data Type
Description
Type
2
Integer 8
Int8
3
Integer 16
Int16
4
Integer 32
Int32
5
Unsigned 8
Uint8
6
Unsigned 16
Uint16
7
Unsigned 32
Uint32
9
Visible string
VisibleString
Table 5.7
Parameter Lists
VLT
®
Micro Drive FC 51 Programming Guide
54
MG02C602 - VLT
®
is a registered Danfoss trademark
5
5