Table 78: Charge switch failure voltage (0x5121 / 0x158)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x5121
0x158
Charge switch
failure voltage
Trip lock
Indicates a malfunction of the in-
ternal charge circuit.
Chg switch
fail
9.3.44 EE Checksum Error (parameter missing) (0x5530 / 0x10A)
This error is valid for PSM 510, DAM 510, ACM 510, and SDM 511/SDM 512.
Table 79: EE Checksum Error (parameter missing) (0x5530 / 0x10A)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x5530
0x10A
EE Checksum Error (pa-
rameter missing)
Trip lock
Missing parameter in internal de-
vice configuration.
config err
9.3.45 Parameter error (0x6320 / 0x10B)
This error is valid for PSM 510, DAM 510, ACM 510, and SDM 511/SDM 512.
Table 80: Param err (0x6320 / 0x10B)
Code
PROFINET
®
code
Name
Severity (warning/error/trip
lock)
Description
LCP name
0x6320
0x10B
Parameter error
Trip lock
A parameter has an invalid value.
param err
9.3.46 Conf par ver (0x6382 / 0x15D)
This error is valid for PSM 510, DAM 510, ACM 510, and SDM 511/SDM 512.
Table 81: Configuration parameters version error (0x6382 / 0x15D)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x6382
0x15D
Configuration param-
eters version error
Trip lock
Configuration parameter set version mis-
match: parameter set is not valid for this
device.
conf par ver
9.3.47 Configuration parameters limits error (0x6383 / 0x164)
This error is valid for PSM 510, DAM 510, and ACM 510.
Diagnostics
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
182 | Danfoss A/S © 2019.10
Summary of Contents for VLT MSD 510
Page 1: ...Operating Guide VLT Multiaxis Servo Drive MSD 510 System...