0-65 Personal Menu Password
Range:
Function:
200
*
[0 - 999 ] Define the password for access to the My
Personal Menu via the [Quick Menu] key. If
0-66 Access to Personal Menu w/o Password
is
set to
Full access
[0], this parameter will be
ignored.
0-66 Access to Personal Menu w/o Password
Option:
Function:
[0]
*
Full access Disables password defined in
[1]
Read only Prevents unauthorized editing of My Personal
Menu parameters.
[2]
No access Prevents unauthorized viewing and editing of
My Personal Menu parameters.
If
0-61 Access to Main Menu w/o Password
is set to
Full
access
[0], this parameter will be ignored.
3.2.8 0-7* Clock Settings
Set the time and date of the internal clock. The internal
clock can be used for e.g. Timed Actions, energy log, Trend
Analysis, date/time stamps on alarms, Logged data and
Preventive Maintenance.
It is possible to program the clock for Daylight Saving
Time / summertime, weekly working days/non-working
days including 20 exceptions (holidays etc.). Although the
clock settings can be set via the LCP, they can also be set
along with timed actions and preventative maintenance
functions using the MCT 10 software tool.
NOTE
The frequency converter has no back up of the clock
function and the set date/time will reset to default
(2000-01-01 00:00) after a power down unless a Real Time
Clock module with back up is installed. If no module with
back up is installed, it is recommended the clock function
is only used if the frequency converter is integrated into
the BMS using serial communications, with the BMS
maintaining synchronization of control equipment clock
times. In
it is possible to program for a
Warning in case clock has not been set properly, e.g. after
a power down.
NOTE
If mounting an Analog I/O MCB 109 option card, a battery
back-up of the date and time is included.
0-70 Date and Time
Range:
Function:
Size related
*
[ 0 - 0 ] Sets the date and time of the internal
clock. The format to be used is set in
and
.
0-71 Date Format
Option:
Function:
Sets the date format to be used in the LCP.
[0]
YYYY-MM-DD
[1]
DD-MM-YYYY
[2]
*
MM/DD/YYYY
0-72 Time Format
Option:
Function:
Sets the time format to be used in the LCP.
[0]
24 h
[1]
*
12 h
0-74 DST/Summertime
Option:
Function:
Choose how Daylight Saving Time/Summertime
should be handled. For manual DST/Summertime
enter the start date and end date in
and
[0]
*
Off
[2]
Manual
0-76 DST/Summertime Start
Range:
Function:
Size related
*
[ 0 - 0 ] Sets the date and time when
summertime/DST starts. The date is
programmed in the format selected in
.
0-77 DST/Summertime End
Range:
Function:
Size related
*
[ 0 - 0 ]
0-79 Clock Fault
Option:
Function:
Enables or disables the clock warning, when the
clock has not been set or has been reset due to a
power-down and no backup is installed. If MCB
109 is installed “enabled” is default
[0]
*
Disabled
[1]
Enabled
Parameter Description
VLT
®
HVAC Drive Programming Guide
34
MG.11.CC.02 - VLT
®
is a registered Danfoss trademark
3
3