25
25
Danfoss District Energy
VI.GP.P2.02
DKDHR
Instructions for installation and use
VX Solo II substations
Type
Radiator Circuit
Floor Heating Circuit
VX Solo II H
(ECL 210/A230), page 4
AHQM / AMV 150
VX Solo II H2
(ECL 210/A260), page 5
AHQM / AMV 13
VMV / AMV 150
VX Solo II HWP
(ECL 210/A237), page 6
VS2 / AMV 150
VX Solo II HWP
(ECL 210/A247), page 7
AHQM / AMV 150
VX Solo II H2WP
(ECL 210/A260), page 8
VS2/AMV13
VMV / AMV 150
VX Solo II H2WP
(ECL 310/A377), page 9
AHQM / AMV 13
VMV / AMV 150
VX Solo II HWS
(ECL 210/A237), page 10
AHQM / AMV 13 *
VX Solo II HWS
(ECL 210/A247), page 11
AHQM / AMV 150 *
VMV / AMV 150
VX Solo II H2WS
(ECL 210/A267), page 12
AHQM / AMV 13 *
VMV / AMV 150
Danfoss ECL Comfort 210 or 310
The temperature for the heating circuits can be controlled electroni-
cally by a Danfoss ECL 210 or 310 controller. The ECL controller is
supplied with an ECL Application Key , which contains information
about application, language and factory settings, adapted to the
type of system, for which it is ordered.
Note! Various applications can be loaded.
The controller is factory-set for local language and the running time
for the actuator (heating circuit) is preset for the actual application.
General controller settings such as “Time and Date” must be entered
during commissioning of the controller. And also the desired supply
flow temperature must be set.
Please refer to the enclosed manufacturer instructions for the ECL
210/310 controller in order to
set the required temperature for
the heating circuit
:
ECL Application Key Box with ECL Comfort 210/310 user guide and
mounting guide, for further information.
We recommend that your order commissioning of the controller with
your local Danfoss representative.
Note, in systems that feature only floor heating it is important that the
supply temperature does not exceed 35°C, and ALWAYS check the in-
structions from the floor supplier ( typically for wooden floors).
Actuator(s) + valve(s)
For substations fitted with a Danfoss ECL controller, electronic
actuator(s) and control valve(s) will in combination with the ECL con-
troller control the secondary side of the substation.
Below schedule states the controller application as well as the actua-
tor/valve combination for control of the heating circuit(s):
* will also control the inlet temperature for the DHW cylinder circuit.
Please see page 31.
In the following pages you will find more information about the
actuators and valves.